Eclipse Magnetics Micromag HP/80NPT Operating Instructions Manual Download Page 3

5

4

1.3 Overview

Details of magnetic circuits showing open flow path through bowl even when core is fully 
contaminated.

2  Technical data

2.1  Performance data

Application ambient temperature: 

32-284°F (0-140°C)

Design temperature:  

302°F (150°C)

Operating design pressure: 

1160 psi (80 bar)

Throughput:  

MM5/HP/80NPT 

18 gallons/minute

 

MM10/HP/80NPT  26 gallons/minute

 

MM20/HP/80NPT  40 gallons/minute

Vessel: Stainless Steel
 

  

Magnetic characteristics 

max. operating temperature:   

NdFeB HT-material 284°F (140°C)

Port size and contamination capacity 

 5

  unit –  1

” 

NPT  

2.2 lbs capacity

 10

  unit –   1

” 

NPT 

4.4 lbs capacity

 20

  unit –   1 ½

 NPT 

8.8 lbs capacity

2.2  Noise data sheet

Sound pressure level, measurement according to DIN 45635: 

 

Idling 

< 70 dB (A)

Conveying 

< 70 dB (A)

2.3 

Dimensions

 5

  unit: A = 9.75 inches (247mm)

 10

  unit: A = 14.37 inches (365mm)

 20

  unit: A = 24.61 inches (625mm)

A

¯116

¯138

Summary of Contents for Micromag HP/80NPT

Page 1: ...de to ensure the accuracy of the information in this publication please note that specifications may change without notice Eclipse Tools North America Inc 442 Millen Road Unit 9 Stoney Creek ON L8E 6H...

Page 2: ...APPROVED PRODUCT 1 2 Used symbols Important notes Danger notes Safety notes Contents 1 Introduction 1 1 Range of application 3 1 2 Used symbols 3 1 3 Overview 4 2 Technical data 2 1 Performance data 5...

Page 3: ...e MM10 HP 80NPT 26 gallons minute MM20 HP 80NPT 40 gallons minute Vessel Stainless Steel Magnetic characteristics max operating temperature NdFeB HT material 284 F 140 C Port size and contamination ca...

Page 4: ...s above the specific operating temperature 2 NO oscillating vibrations 3 NO impacts 4 NO strong external magnetic flux fields 5 Pay attention to the cleaning and maintenance of the system 4 2 General...

Page 5: ...nit is to be installed as follows Before installation ensure that all supplies are isolated Micromag HP 80NPT is to be installed vertically with the bowl pointing upwards this allows fluid to drain ou...

Page 6: ...f the lid seal and replace if damaged Turn on the material flow After each clean the housing should be wiped over to avoid the build up of excessive dirt dust Do not use corrosive substances to clean...

Page 7: ...the goods is not exceeded IATA Dangerous Medium Prescript Cap 3 9 1 1 Magnetised Material ICAO Instructions Packing Instruction 902 Permanent Magnets where possible should have keeper bars installed...

Page 8: ...remove handling safeguards once all installation work has been completed When handling in a loading area make sure the unit cannot topple over or slip Damage caused during transportation must always b...

Reviews: