background image

7

6

3  Design and method of operation

3.1  Method of operation

The single magnetic core is integrated in an aluminium housing and forms one unit e.g. fitted 
in series with the pipe-line. 

The flow is arranged in such a manner that the material that is to be cleaned is well 
distributed and comes intimately into contact with the magnetic field. 

3.2 Construction

• 

All stainless steel construction with optional internal coatings

• 

Viton ‘O’ ring lid seals

• 

High intensity magnetic core

4 Safety

4.1  Intended use

The inline liquid filter is designed for installation into pressurised pipe lines working at up to 
1160 psi (80 bar). All pipeline connections are to be installed accurately and sealed to prevent 
the loss of pressure/fluid. 

The lid seal is to be maintained in a good condition. 

To ensure that the supplied magnets maintain their high level of performance, attention 
must be paid to the following conditions:

1.  NO temperatures above the specific operating temperature

2.  NO oscillating vibrations

3.  NO impacts

4.  NO strong external magnetic flux fields

5.  Pay attention to the cleaning and maintenance of the system

4.2  General preventive measures

The core is constructed with strong magnets. The handling of ferrous tools (e.g. with 
maintenance or cleaning) etc. can cause risk of injury for the personnel due to the magnetic 
attraction. Special measures regarding the presence of ferrous items have to be considered 
when handling magnetic material.

4.3  Dangers of not adhering to safety notes

Using this equipment in a manner not intended can be hazardous.

4.4  Safety notes for operation and maintenance

Maintenance work is to be executed only by technical personnel. With work on pneumatic, 
hydraulic, pressurised or electrical services, the supply lines are to be isolated prior to any 
cleaning or maintenance actions. 

Prior to any maintenance work being carried out, the process, equipment used and personnel 
must be risk assessed and deemed suitable to conduct that task. All work is to be carried out 
in accordance with local and legislative regulations. 

Summary of Contents for Micromag HP/80NPT

Page 1: ...de to ensure the accuracy of the information in this publication please note that specifications may change without notice Eclipse Tools North America Inc 442 Millen Road Unit 9 Stoney Creek ON L8E 6H...

Page 2: ...APPROVED PRODUCT 1 2 Used symbols Important notes Danger notes Safety notes Contents 1 Introduction 1 1 Range of application 3 1 2 Used symbols 3 1 3 Overview 4 2 Technical data 2 1 Performance data 5...

Page 3: ...e MM10 HP 80NPT 26 gallons minute MM20 HP 80NPT 40 gallons minute Vessel Stainless Steel Magnetic characteristics max operating temperature NdFeB HT material 284 F 140 C Port size and contamination ca...

Page 4: ...s above the specific operating temperature 2 NO oscillating vibrations 3 NO impacts 4 NO strong external magnetic flux fields 5 Pay attention to the cleaning and maintenance of the system 4 2 General...

Page 5: ...nit is to be installed as follows Before installation ensure that all supplies are isolated Micromag HP 80NPT is to be installed vertically with the bowl pointing upwards this allows fluid to drain ou...

Page 6: ...f the lid seal and replace if damaged Turn on the material flow After each clean the housing should be wiped over to avoid the build up of excessive dirt dust Do not use corrosive substances to clean...

Page 7: ...the goods is not exceeded IATA Dangerous Medium Prescript Cap 3 9 1 1 Magnetised Material ICAO Instructions Packing Instruction 902 Permanent Magnets where possible should have keeper bars installed...

Page 8: ...remove handling safeguards once all installation work has been completed When handling in a loading area make sure the unit cannot topple over or slip Damage caused during transportation must always b...