148
Set
tings
•
<GPO Value>
is a numeric value in the range [0-1], i.e. it can only take the value 0
or 1 (relay contact open or closed).
•
<Rate>
is a numeric value in the range [1-10] that specifies the frequency of sending
VU meters to the client, in number per second (default = 3).
•
"<Device Name>"
indicates the device name in double quotes to allow for names
with spaces.
•
<Error ID>
is a numeric value encoding a type of error.
•
"<Error Description>"
is a text string enclosed in double quotes containing a
description of the error.
10.2
VIDA PARAMETERS
Communication between client and device
is established with a
n initial
SYSTEM
CONNECT
message
. If not, commands from the client to the device will be ignored by the
device.
See the chapter TP-NET Protocol Introduction for more information.
The
INC
and
DEC
commands generate a
DATA
command response from the
device
, containing the resulting LEVEL value, incremented or decremented. When the
INC
or
DEC
command attempts to adjust to a value outside the minimum and maximum
allowed limits, no response will be produced (no
DATA
command will be sent).