76
Set
tings
2.
Calculate:
Button for resetting the Smart VersaPower settings.
Button available if Smart VersaPower is enabled.
The button opens a window to reconfigure the parameters
.
A.
Configuration of parameters for an output
:
•
Impedance selector indicator
on the rear panel, to display the status of the
impedance selector
.
•
Sensitivity
: selection of the sensitivity of the input signal to the amplifier.
•
Max RMS Power
: setting of the maximum power delivered by an amplified
output. The value must be between 0 W and the maximum power of the
amplifier. The sum of the power of the 4 outputs may not exceed the
maximum power of the amplifier.
B.
Indicates the power used
across the 4 channels.
C.
Cancel
:
cancels the configuration
. Smart VersaPower will remain disabled and
no changes will be applied.
Apply
:
applies the changes made
to the Smart VersaPower configuration. If there
is an error, e.g. exceeding the maximum power, it will not let you continue.
3.
VersaPower Smart Monitor
Displays the current status of the Smart VersaPower configuration.
•
VU for the amplified output
: Clicking on a value shows different measurements
of the signal before and after the amplifier.
•
Settings:
o
Sensitivity
: selected sensitivity.
o
Max RMS Power
: maximum power that can be delivered by an output.
o
Max Peak Power
: maximum peak power at an output. Not editable.
o
Gain: gain
applied to the output to obtain the indicated power value.