60 / 97
8.5
Individual manual checking of drives in jogging mode
The drives are to be checked upon the adapting of the machine constants.
This is best made by means of a mechanical jogging mode of the single drives. It is to be
checked whether the configured drives X, Y,.. behave in compliance with the presetting
Tabelle 33:
Table 33:
Individual manual checking of drives in jogging mode
Steps in stdHMI
Description
Setup F9
(or Diagnostics F12)
Manual travel F2
(Axis setting F1)
Modal travel F1
A single drive is selected, the selected drive can be recog-
nized by the green highlighted command value
S3
Selected drive turns in jogging mode in positive direction
Travel - S4
Selected drive turns in jogging mode in negative direction
Axis S5
Axis change-over is recognized by the change over of the
green command value display
Ov/- S6, S7
The drive speed can be changed by means of Override
Abbildung 37:
Figure 37:
Manual travel in StdHMI
8.6
Programming as per DIN 66025
The programming as per DIN66025 will be explained with a simple example. The editor for
programming is called with the function key F11.