20 / 97
1.4.6
Error indication
1.4.6.1
Error indication during booting
Probable errors in the booting phase are signalled by the following indication pattern. The
indication shows the pattern sequentially with 2 characters/sec. The indication is made until
the controller is reset (exception: start of the boot monitor).
Tabelle 12:
Table 12:
Error indication during booting, ENC66
7-segment indicator
Meaning
Start of boot
monitors
E01
RAM error
E02
Checksum error in boot loader (FPROM)
E05
unknown FPROM type
E06
Error during loading of firmware from FPROM
x
E07
Error during start of firmware
x
E88
Processor exception
A running light in the 7-segment indicator (two adjacent segments rotating in clockwise di-
rection) shows that the boot monitor is active.
The boot monitor is activated either by the user or by the boot loader, if the start of the
operating system has not been made successfully after E06 and E07.
1.4.6.2
Error indication in normal operation
Probable errors are signalled by the following indication pattern. The indication shows the
pattern sequentially with 2 characters/sec. The indication is made until the controller is re-
set.
Tabelle 13:
7-segment
indicator
Meaning
E104
ZST / I2C initialization failed
E105
ZST / EEPROM initialization failed
E106
ZST / RTC initialization failed
E107
UTI / Power failure of real-time clock, time invalid
E108
ZST / Identification of the ExC66-expansion card failed
F001
SYS / Incorrect segment at freemem()
F002
SYS / Invalid segment at freemem
F003
SYS / Invalid argument at PutMsg()
F004
SYS / Unexpected termination of a task
Table 13:
Error indication in normal operation, ENC66