ECI MOVFR-LCD Installation Manual
Electronic Controls, Inc.
7073 North Atlantic Ave. Cape Canaveral, FL 32920
800-633-9788
P a g e
|
8
5
System Overview
5.1
Control Board
Figure 1 - Control Board
5.1.1
Electrical
5.1.2
Connections
5.1.2.1
Input Signals
•
CLOSE –
Any 24 to 240 VAC/VDC input between CLOSE and COM
will produce a CLOSE
operation.
•
OPEN –
Any 24 to 240 VAC/VDC input between OPEN and COM
will produce a OPEN
operation.
•
NUDG –
Any 24 to 240 VAC/VDC input between NUDGE and COM, with a CLOSE input
present,
will produce a NUDGE operation
•
HEAVY –
Any 24 to 240 VAC/BDC input between HEAVY and COM, with OPEN or CLOSE
valid, will move the door at the HEAVY parameter settings.
•
COM –
Common input for OPEN, CLOSE, and NUDGE inputs.
5.1.2.2
Output Relay Contacts
•
AUX NO
•
AUX COM Auxiliary Relay contacts rated at 230V 10A. Energized when AUX optical
•
AUX NC
sensor blocked
•
DPM NO
•
DPM COM DPM Relay contacts rated at 230V 10A. Energized when DPM optical
•
DPM NC sensor blocked