background image

 

ECI MOVFR-LCD Installation Manual 

 

 

Electronic Controls, Inc. 

 

7073 North Atlantic Ave. Cape Canaveral, FL 32920 

 

800-633-9788 

 

www.eciamerica.com

 

P a g e

 | 

19

 

Figure 13 - Drill Pattern placement 

 

 

With the drill template secure into the corner of the operator, drill the five (5) 5/32 inch holes at 
locations shown on the template. 

 

Drill a 6

th

 .106” dia hole for self-tapping grounding screw in area shown in figure 13.  

 

Remove the template and insert standoffs supplied with boards into the 5 new holes as shown in 

Figure 14 - Standoff Placement

 

 

Figure 14 - Standoff Placement 

 

 

Using hardware supplied with the board, mount the Control and Drive boards as shown in Figure 
15 -ECI MOVFR LCD Installed.
  Connect communication cable (supplied with boards) between 
Control and Drive boards. 
 

Drill .106” hole here for 

self-tapping grounding 

screw 

Summary of Contents for MOVFR

Page 1: ...ECI MOVFR LCD Door Board Installation Manual REV 2 2 DATE 5 14 2018 MANUAL NUMBER 37 Electronic Controls Inc 7073 North Atlantic Ave Cape Canaveral FL 32920 WWW ECIAMERICA COM 800 633 9788 ...

Page 2: ...FL 32920 800 633 9788 www eciamerica com P a g e 2 REV DATE DESCRIPTION 1 0 10 25 2017 INITIAL RELEASE 1 2 11 2 2017 Added installation Kits AUTO Operation 2 0 4 13 2017 Added new logo 2 1 5 4 2018 Removed CL HCL Max Speed Added Light curtain parameter 2 2 5 14 2018 Added drill template directions ...

Page 3: ...mula Systems 9 5 1 2 3 2 Tri Tronics Leading Edge 9 5 1 3 User Interface 10 5 1 3 1 LCD Screen Main Menu 10 5 1 3 2 Control Board LEDs 10 5 1 3 3 Keypad 11 5 1 3 4 Switches 11 5 1 4 CAM Optical Sensors 12 5 1 5 Operation 12 5 1 5 1 Edit Parameters 12 5 1 5 1 1 Standard Parameter settings with defaults 12 5 1 5 1 2 Heavy Door Parameter settings with defaults 14 5 1 5 1 3 Input Voltage setting Param...

Page 4: ...ng MOVFR 0001N 17 6 2 Replacing MOVFR 0069N 20 7 Initial Power Up and Test 22 7 1 Manual Operation 22 8 Adjustments 23 8 1 Speed Profiles 24 8 1 1 Closing Speed Profile 24 8 1 2 Closing CAM Sensor Sequence 24 8 1 3 Open Speed Profile 24 8 1 4 Open CAM Sensor Sequence 25 8 2 CAM Settings 25 8 2 1 Right Hand CAMs 25 8 2 2 Left Hand CAMs 26 9 AUTO Operation 26 10 Drill template for MOVFR 0001N replac...

Page 5: ... There may be local regulatory or government offices that can also help determine which codes and standards are necessary for safe installation and operation Equipment damage or serious injury to personnel can result from failure to follow all applicable codes and standards We do not guarantee the products described in the publication are suitable for your particular application nor do we assume a...

Page 6: ...for an external handheld device All control inputs are compatible with 24 to 230 volt AC or DC signal or dry contact voltages 3 Conventions Used When you see the notepad icon in the left hand margin the paragraph to its immediate right will be a special note Notes represent information that may make your work quicker and more efficient The word NOTE in boldface will mark the beginning of the text ...

Page 7: ...or removing access covers conduits wire way or electrical devices When working on car canopy always be aware of where the sides of the car are located Use properly grounded cords and power equipment ground fault circuit interrupters Make sure there are proper clearances in hoist way between the car and other devices Before connecting wiring cover sharp edges to keep hands and arms from being cut A...

Page 8: ...t between OPEN and COM will produce a OPEN operation NUDG Any 24 to 240 VAC VDC input between NUDGE and COM with a CLOSE input present will produce a NUDGE operation HEAVY Any 24 to 240 VAC BDC input between HEAVY and COM with OPEN or CLOSE valid will move the door at the HEAVY parameter settings COM Common input for OPEN CLOSE and NUDGE inputs 5 1 2 2 Output Relay Contacts AUX NO AUX COM Auxiliar...

Page 9: ...ith Light Curtain When there is an obstruction of the edges the REOPEN LED will light and the REOPEN relay will energize sending a command to the controller to OPEN the doors The light curtain connectors CN4 and CN5 are interchangeable 5 1 2 3 1 Formula Systems The REOPEN relay contacts should be connected to the controller as shown in Figure 2 Reopen Contact Connection Figure 2 Reopen Contact Con...

Page 10: ...defaults hi lighted will load the default settings for all parameters Diagnostics 1 Pressing ENTER with Diagnostics hi lighted will display the first diagnostics screen Diagnostics 2 Pressing ENTER with Diagnostics hi lighted will display the second diagnostics screen Technical Support not shown Pressing ENTER with Technical support hi lighted will display the technical support screen Rotate scree...

Page 11: ...igh speed close when FSC sensor is open during a CLOSE FSC Final Close Speed Speed setting is CL final speed Illuminated during final close speed when FSO sensor is blocked during a CLOSE AUX Illuminated when AUX sensor is blocked DPM Illuminated when DPM sensor is blocked DOL Door Open Limit Illuminated when DOL sensor blocked DCL Door Close Limit Illuminated when DCL sensor is blocked STALL REVE...

Page 12: ...en cycle MSO Medium Speed Open sensor Valid only during an open cycle DOL Door Open Limit sensor When blocked will energize the DOL relay FSC Fast Speed Close sensor Valid only during a close cycle DPM Car Door Closed Sensor When blocked will energize the DPM relay DCL Door Close Limit sensor When blocked will energize the DCL relay AUX Auxiliary sensor When blocked will energize the AUX relay 5 1...

Page 13: ...ion in the close direct A lower value produces a quicker acceleration Default setting is 100 Min setting is 1 Max setting is 255 CL decel Sets the deceleration in the close direction A lower value produces a quicker deceleration Default setting is 100 Min setting is 1 Max setting is 255 OP quick stp rev Determines how quickly the door opens after changing direction during a reopen A higher value p...

Page 14: ...y door parameters are enabled when the HEAVY input is valid during AUTO operation and when the HEAVY switch is on in MANUAL operation These parameters are the same as the standard parameters so only the default and range settings are listed HCL hold torq Default setting is 0 Min is 0 and max is 100 HCL hold sp Default setting is 0 Min is 0 and max is 100 HCL torque Default setting is 15 Min is 1 a...

Page 15: ...r to 1 without a light curtain connected will cause to door to remain open at all times 5 1 5 2 Load Defaults Selecting LOAD DEFAULTS will set all parameters to their default settings 5 1 5 3 Diagnostics 1 Figure 7 Diagnostics 1 Screen VBUS present DC voltage for motor driver 0s 16 second timer Resets at each OPEN or CLOSE command Will time down to 0 then all motor drive is stopped until present c...

Page 16: ... fuse 5 2 2 Frequency Board Connections L1 and L2 240 VAC input power U V W motor connections Chassis Ground GS and GS1 Gate switch dry contact RJ45 Communications port to Control Board 5 2 3 Frequency Board LEDs PWR On when power is present BRAKE On all the time FAULT On when no communications between Control board and Drive board RIGHT On when motor turning a direction LEFT On when motor turning...

Page 17: ... 0001N Installation Kit Disconnect power from drive Remove Control board and Drive shown in Figure 10 MOVFR 0001N shown without CAMs Figure 10 MOVFR 0001N Remove the standoffs indicated in Figure 11 Standoff Removal leaving the 2 standoffs on the far right and the 2 nylon standoffs in the center Standoffs can be removed using a pair of pliers and snapping the standoff See Figure 12 Snapping Off St...

Page 18: ...800 633 9788 www eciamerica com P a g e 18 Figure 11 Standoff Removal Figure 12 Snapping Off Standoff Remove drill template from manual last page of manual Fold or cut page of drill template along dotted lines and place in top left corner of operator as shown in Figure 13 Drill Pattern placement Remove Keep ...

Page 19: ...he template Drill a 6th 106 dia hole for self tapping grounding screw in area shown in figure 13 Remove the template and insert standoffs supplied with boards into the 5 new holes as shown in Figure 14 Standoff Placement Figure 14 Standoff Placement Using hardware supplied with the board mount the Control and Drive boards as shown in Figure 15 ECI MOVFR LCD Installed Connect communication cable su...

Page 20: ...tial Power Up and Test 6 2 Replacing MOVFR 0069N Figure 16 MOVFR 00069N Installation Kist Remove the Control Board and Drive shown in Figure 17 MOVFR 0069N Mount and secure the ECI MOVFR LCD Control board and Drive board as shown in Figure 18 ECI MOVFR LCD Installed Connect communication cable CAT5 between Control and Drive Boards Make all connections to the Drive and Control boards at this time a...

Page 21: ...CI MOVFR LCD Installation Manual Electronic Controls Inc 7073 North Atlantic Ave Cape Canaveral FL 32920 800 633 9788 www eciamerica com P a g e 21 Figure 17 MOVFR 0069N Figure 18 ECI MOVFR LCD Installed ...

Page 22: ...ress button until INPUT VOLTAGE is highlighted Press ENTER button and set to proper input voltage using button Press ENTER then ESC buttons when complete Move curser down to DIAGNOSTICS 1 and press ENTER o LCD should show NOTE that the VBUS and TEMPs are estimates With the AUTO MAN switch in MAN position set the CLOSE OPEN switch to the OPEN position If motor moves in wrong direction remove power ...

Page 23: ...ight with DCL due to the CL HOLD SP and TORQ settings are at default 0 o Go to EDIT PARAMETERS screen and change CL hold torq and CL hold sp to 1 NOTE these settings will have to be set 1 to ensure enough force to hold doors NOTE HOLDING power should not exceed 15W to prevent heating motor which can reduce its life o The HOLDING LED should light on the next close cycle 8 Adjustments At this time a...

Page 24: ...tic Ave Cape Canaveral FL 32920 800 633 9788 www eciamerica com P a g e 24 8 1 Speed Profiles 8 1 1 Closing Speed Profile Figure 19 Close Speed Profile 8 1 2 Closing CAM Sensor Sequence Figure 20 Close CAM Sensor Sequence 8 1 3 Open Speed Profile Figure 21 Open Speed Profile ...

Page 25: ...c Controls Inc 7073 North Atlantic Ave Cape Canaveral FL 32920 800 633 9788 www eciamerica com P a g e 25 8 1 4 Open CAM Sensor Sequence Figure 22 OPEN CAM SENSOR Sequence 8 2 CAM Settings 8 2 1 Right Hand CAMs Figure 23 Right Hand CAM Settings ...

Page 26: ...0 800 633 9788 www eciamerica com P a g e 26 8 2 2 Left Hand CAMs Figure 24 Left Hand CAM Settings 9 AUTO Operation Go to EDIT PARAMETERS and change the INPUT VOLTAGE parameter to the proper voltage for your system Switch the AUTO MAN switch to AUTO position Door operator is now ready for normal operation ...

Page 27: ...Installation Manual Electronic Controls Inc 7073 North Atlantic Ave Cape Canaveral FL 32920 800 633 9788 www eciamerica com P a g e 27 10 Drill template for MOVFR 0001N replacement FOLD OR CUT PAGE ALONG DOTTED LINES ...

Reviews: