ECI MOVFR-LCD Installation Manual
Electronic Controls, Inc.
7073 North Atlantic Ave. Cape Canaveral, FL 32920
800-633-9788
P a g e
|
12
•
AUTO / MAN –
2 position switch. AUTO position is for normal operation. MAN position is for
controlling the doors using OPEN, CLOSE, HEAVY and NUDGE switches.
•
CLOSE / OPEN –
3 position switch.
Center position no function. With AUTO/MAN switch in
manual position this controls opening and closing the doors.
•
NUDGE –
3 position switch.
Center position no function. With AUTO/MAN switch in MAN
and the CLOSE switch in CLOSE this switch puts door at NUGDING speed.
•
HEAVY / RESET –
3 position switch.
Center position no function. HEAVY position moves
doors at heavy SPEED SETTING with AUTO/MAN at MAN and using OPEN/CLOSE switch.
RESET position resets any active faults.
5.1.4
CAM Optical Sensors
•
FSO/SSO –
Final Speed Open and Slow Speed Open sensor. Valid only during an open cycle.
•
MSO –
Medium Speed Open sensor. Valid only during an open cycle.
•
DOL –
Door Open Limit sensor. When blocked will energize the DOL relay.
•
FSC –
Fast Speed Close sensor. Valid only during a close cycle.
•
DPM –
Car Door Closed Sensor. When blocked will energize the DPM relay.
•
DCL –
Door Close Limit sensor. When blocked will energize the DCL relay.
•
AUX –
Auxiliary sensor. When blocked will energize the AUX relay.
5.1.5
Operation
5.1.5.1
Edit Parameters
Figure 6 - Edit Parameters Menu
Pressing the ENTER button while EDIT PARAMETERS is highlighted will display the parameters show
in Figure 6 - Edit Parameters Menu. Pressing the – button moves the curser/highlight down. Pressing
ENTER selects the highlighted parameter and the + and – buttons are used to change setting.
5.1.5.1.1
Standard Parameter settings with defaults
•
CL hold torq. –
Enabled when the door reaches DCL and parameter is set to a value greater than
0. Together with CL Hold sp will prevent the door from drifting out of the DCL. Default setting
is 0. Max setting is 100.
ECI MOVFR
(C) 2018 ECI Inc.
CL hold torq. 50
CL hold sp. 0
CL torque 0
CL High speed 45