![EchoLab MVS3 Operator'S Manual Download Page 6](http://html1.mh-extra.com/html/echolab/mvs3/mvs3_operators-manual_3894833006.webp)
INSTALLATION
page 6
Sync modes - Command 6
MODE
OPERATION
Subcarrier
Horizontal and vertical sync are locked to the external genlock
input. Subcarrier is free-running, generated from the internal
crystal oscillator.
Internal
Color burst and sync generated internally.
Genlock
Burst and sync are locked to an external NTSC (or PAL) signal
connected to the GENLOCK input. Burst phase and horizontal
phase are adjustable from the front panel using the calibration
commands; see COMMANDS in the Production section.
Video Inputs
Ten (6 standard, 4 optional) zero-timed terminating video inputs are available for any
synchronous NTSC or monochrome source, composite (preferred) or non-composite.
One DSK FILL input is also available for key fill inputs.
Video Outputs
One PREV and two PROG outputs are provided in the selected video mode. Also, a
composite PREV and PROG output are available at all times. Three BLACK outputs can
be used to synchronize genlockable cameras.
Control Panel connections
Up to 1000' (300M) of 75 ohm coax is used to connect the serial digital data connectors,
FA and FB, to the control panel. RS-423 standard data transmission is used for bi-
directional communication to the panel. A wall-mount transformer supplies 9-12 volts
DC at 1.5 amps to the panel.