Echoflex Solutions Installation Guide
SmartSpace Controller–Gen 2
Connect Power Input and Relay Output
The power input and relay output wiring exits the SmartSpace Controller–Gen
2 through the knockout mount on the enclosure.
1.
Connect the power input wiring.
a.
Connect the white wire (14 AWG) to the incoming neutral wire
from the breaker panel and the neutral wire of the lighting load.
b.
Connect the black power input wire (12 AWG) to the line input
feed wire (hot) from the breaker panel.
2.
Connect the relay output wiring. A Single Zone controller has one (red)
relay output wire (12 AWG). A Dual Zone controller has two relay
output wires (12 AWG): Zone 1 is red and Zone 2 is red/white.
a.
Connect the Zone 1 relay output wire (red) to the hot input of the
load.
b.
For the Dual Zone controller, connect the Zone 2 relay output
wire (red/white) to the hot input of the second load.
SmartSpace Controller–Gen 2
Page 7 of 12
Echoflex Solutions