Installation should follow all local codes and standard electrical practices.
Ensure that the junction box is clean and free of obstructions and that all
wiring is installed correctly.

WARNING:

Risk of electric shock! This device utilizes high voltage

and should only be installed by a qualified installer or electrician. Follow
all local codes for installation. Before terminating the AC power wiring
verify that the main breaker is in the off position and follow the proper
lockout/tag out procedures per NFPA Standard 70E.

AVERTISSEMENT:

Risque de décharge électrique! Cette appareil

utilise une haute tension et ne doit être installé que par un installateur
qualifié ou un électricien. Suivez tous les codes locaux pour l'installation.
Avant de raccorder le câblage du courant alternatif, vérifiez que le
disjoncteur principal est en position d'arrêt et suivez les procédures de
Consignation/Déconsignation prescrites par la norme NFPA 70E.

WARNING:

For indoor use only! Must install to an electrical junction

box or wireway.

AVERTISSEMENT:

Uniquement pour usage d'intérieur! Doit être

installé sur une boîte de raccordement électrique ou un chemin de câbles.

1.

Locate the circuit breaker panel and turn off the power to the lighting
circuit.

2.

To gain access to the line voltage wiring, remove the cover plate and
other hardware from the junction box at the load.

3.

Mount the SmartSpace Controller–Gen 2 to the exterior of the junction
box or panel using the 1/2 in threaded nipple. Use the provided 1/2 in
conduit locknut to secure the SmartSpace Controller–Gen 2 to the
junction box or panel.

Note:

Follow all local code requirements for terminating wire.

Notice that the harness wires on the controller are pre-stripped
for your installation convenience.

Use appropriately sized wire nuts (not provided) to terminate
power wires, and use included WAGO

®

connectors to

terminate EchoConnect wires.

SmartSpace Controller–Gen 2

Page 5 of 12

Echoflex Solutions

Summary of Contents for Elaho SmartSpace Controller-Gen2

Page 1: ...2019 12 Overview The Elaho SmartSpace Controller Gen 2 provides fully rated 20 A relays for direct control of individual fixtures or zone power and offers fully isolated 0 10 V dimming control for com...

Page 2: ...onnect EchoConnect is a two wire topology free system that provides the SmartSpace Controller Gen 2 with the flexibility to connect in a system with up to 16 Elaho control products and up to 15 other...

Page 3: ...el supports Power input 120 277 VAC 60 Hz Load rating 20 A general purpose tungsten or resistive 16 A electronic ballast Dual Zone model supports Power input 120 277 VAC 60 Hz Load rating 20 A general...

Page 4: ...nect is a bidirectional protocol that uses one pair of wires data and data for both data and power Echoflex Solutions recommends using Belden 8471 or approved equal Class 2 wire The total combined len...

Page 5: ...osition d arr t et suivez les proc dures de Consignation D consignation prescrites par la norme NFPA 70E WARNING For indoor use only Must install to an electrical junction box or wireway AVERTISSEMENT...

Page 6: ...ire is pulled appropriately Terminate Cat5 wiring using the EchoConnect Cat5 Station Termination Kit and install it using a bus topology See the installation guide that is provided with the Cat5 Stati...

Page 7: ...re of the lighting load b Connect the black power input wire 12 AWG to the line input feed wire hot from the breaker panel 2 Connect the relay output wiring A Single Zone controller has one red relay...

Page 8: ...lack Green Yellow EchoConnect Ground Red Load 1 Red White Load 2 Occupancy Sensor 24 VDC 24 VDC Red Common Black Sensor Input Yellow Dual Zone SmartSpace Occupancy Sensor 24 VDC 24 VDC Red Common Blac...

Page 9: ...erre avant de raccorder tout c blage de commande 0 10V l appareil The 0 10V dimming output wiring exits the SmartSpace Controller Gen 2 through the top nipple of the enclosure with the power wiring 1...

Page 10: ...Zone model only do not set the Zone switch setting to a number higher than 15 If set to 16 both circuits in the controller will be assigned to and controlled on Zone 16 2 Set the Space rotary switch...

Page 11: ...ux Input Mode button to cycle through the available sensor types Troubleshooting Restore Defaults To return the SmartSpace Controller Gen 2 to factory defaults set both rotary switches to 16 and then...

Page 12: ...ert the microSD card in the SD slot on the side of the SmartSpace Controller Gen 2 enclosure The Dim Mode LED will illuminate amber in a triple blink pattern while the firmware is updating and then wi...

Reviews: