background image

SPECIFICATIONS  

 

Rated Performance

 

ECHO Tec:        500 – PRO – 1 

min. 20 gallons –   75ltr. / hour

 

 

 900 – PRO – 2 

min. 38 gallons – 140ltr. / hour 

  1200 – PRO – 3 

min. 50 gallons – 210ltr. / hour 

  1500 – PRO – 4 

min. 60 gallons – 260ltr. / hour 

 
Reverse  Osmosis  performance  varies  with  the  feed  water  temperature  and  salinity.  The  rated 
performance is tested at 26

°

C / 80

°

F water temperature at a salinity of 35g/l.  A decrease in product 

water quantity of 10 to 15% in the first year is normal and expected. 
 

RO Membrane Type:  

Standard size high rejection TFC Polyamide, thin film composite, spiral wound, single pass reverse 
osmosis element. 
 

Salt Rejection: 

min. 99.5% 

 

Salinity Range: 

System 500 / 900

 

up to 50,000 ppm TDS ( NaCl ) 

 

 

 

           1200 up to 40,000 ppm TDS ( NaCl ) 

 

 

 

           1500 up to 36,000 ppm TDS ( NaCl ) 

 

PH Range: 

4 – 11 

 

Chlorine Tolerance: 

1000 ppm hours 

 

Operating Pressure: 

725 to 800 psi (continuous duty) 

 

Feed Water Pressure:

 0 to 60 psi 

 

Feed Water Temperature Range:  

min. 33

°

F / 0.5

°

C, max 113

°

F / 45

°

 

Electrical Power Requirements: 

230V 50Hz single phase 11.2amps at 230V 
220/380/440V 50Hz three phase 3.8amps at 380V 
 
 

Safety Switch Off Functions:

  

1)  High RO pressure: above 1000 PSI 
2)  Low high-pressure pump feed pressure: below 1.5 PSI 
3)  High product salinity (optional)   

All manuals and user guides at all-guides.com

Summary of Contents for 1200-PRO- 3

Page 1: ...NS 6 7 OPERATION INSTRUCTIONS 8 MEMBRANE CLEANING PROCEDURE 9 MAINTENANCE TIMETABLE 10 PRESSURE VESSEL ENDPLUG CHANGING PROCEDURE 11 ELECTRICAL DIAGRAM 12 TROUBLESHOOTING GUIDE 13 14 HIGH PRESSURE PUM...

Page 2: ...on system By understanding the function importance and normal operation of each part in the system the operator can readily diagnose problems when they first develop Such problems are easily corrected...

Page 3: ...hin film composite spiral wound single pass reverse osmosis element Salt Rejection min 99 5 Salinity Range System 500 900 up to 50 000 ppm TDS NaCl 1200 up to 40 000 ppm TDS NaCl 1500 up to 36 000 ppm...

Page 4: ...cartridge filtration system 2 1 Fresh water flush kit with hose and 316SS hose clamps 3 1 Product water tube 10ft 3m 1 Reject hose 10ft 3m with 2pcs 316SS hose clamps 1 Intake hose 10ft 3m with 2pcs...

Page 5: ...take of the desalination system located at the pre filter assembly Secure all hoses with the supplied hose clamps PRODUCT WATER TUBING Connect the product water outlet marked SAMPLE with a test statio...

Page 6: ...the electrical control panel to the FEED position feed pump only and purge the system until all entrapped air has escaped 6 In the AUTO position press the START button until the pressure on the low p...

Page 7: ...lve and the seacock MEMBRANE STORAGE PROCEDURE If you intend to store your watermaker for more than ten days growth of microorganism will degrade the RO membranes performance The RO membranes should b...

Page 8: ...rning label on side of container and observe all safety precautions on label CAUTION Do not mix different cleaning chemicals together Do not use different cleaning chemicals together at the same time...

Page 9: ...rs or when clogged Pre filters Replace or clean elements and clean housings When system intake pressure drops below 5psi Charcoal flush filter Replace element Every 6 months High pressure pump Change...

Page 10: ...it in one fast pull 6 Inspect the end plug for hairline cracks or damages on the O rings and O ring grooves 7 Pull the membrane on the product pipe out of the pressure vessel or remove both plugs and...

Page 11: ...BUTTON NO SELECTOR SWITCH S2 3 POSITION MAINT 4 CONTACTS NO T1 HIGH PRESS SWITCH S4 NC LOW PRESS SWITCH S5 NO TANK FULL SWITCH S6 NC EXTERNAL MAIN IN ELECTRICAL DIAGRAM CONTROL BOX ECHOTEC PRO BHL SER...

Page 12: ...ilter s Inability to Discharge valve chamber Allow more time to prime build up pressure has air trapped within it and ensure that there are no air suction leaks Open valve chambers and allow air to es...

Page 13: ...6D and clean the old Locktite from the plunger bolt 16C and plunger base 16A Replace the plunger with the new one and Locktite the plunger bolt and torque to 120 inch pounds NOTE If there are deposits...

Page 14: ...ere removed from the crankshaft Be certain the bearings are pressed all the way onto the shaft and completely into the crankcase Replace radial shaft seal 11 bearing cover with sight glass 7 and 8 and...

Page 15: ...All manuals and user guides at all guides com...

Page 16: ...The purchaser must pay any transportation or labor expenses incurred in removing and returning the product to the service center The limited warranty does not extend to any system component which has...

Page 17: ...uling rust chemical attack extreme temperatures over 113 F under 33 F drying out or extreme pressures over 1000 psig CAUTION Use of parts not supplied directly by Echo Marine generic parts including b...

Reviews: