Summary of Contents for VERSO200

Page 1: ... et de fonctionnement Operating instruction manual Manual descriptivo y de funcionamiento SDMO Inverseur de sources automatique Automatic transfer switch Inversor de fuentes automático VERSO200 02 08 2013 33514066401_0_1 ...

Page 2: ... switch This applies to both the mains side and the generating set side Read carefully the information provided on the electrical drawing Preliminary checks 3 The electrical box has four 7mm diameter holes for wall mounting or affixing to a suitable metallic bracket Only use suitable professional materials for the mounting bracket The template for mounting the box is shown on the packaging The box...

Page 3: ...monitoring fault source 1 4 Source 2 switch open Source 2 switch closed Position monitoring fault source 2 5 No force switch to source 1 Force switch to source 1 selected 6 No force switch to source 2 Force switch to source 2 selected 7 AUTO mode not selected AUTO mode selected 8 TEST mode not selected TEST mode selected Diagnostics LED functions 8 4 key navigation keypad 9 Access to previous menu...

Page 4: ... genset circuit breaker check voltage and phase sequence If phase rotation is not correct LED 12 turns red open the genset breaker and restore phase sequence Commissioning 10 Source 1 present and parameters are correct Frequency source 2 Voltages phase to neutral of type 3P N Phase voltage between phases of type 3P N Electrical measurements display 11 Displays may be different depending on type of...

Page 5: ...on at source 1 2 AUTOSET OK auto configuration initialising MODE EJP EJP STOR mode engaged France only AUTOSET auto configuration in progress flashing PROGRAM Program inprogress DEL test switchedon On the third and fourth lines the following action messages may be displayed T00 003s 1 0 Transfer Timer 1 OK CONFIRM _____CONFIRM OK Manual confirmation of return to mains T01 005s 2 1 Return to mains ...

Page 6: ...ers A11 N function Range of adjustment Standard range N function Range of adjustment Std settings T00 Loss of source 1 0s to 180s 3 T26 Screen scrolling time 1s to 10s 5 T01 Return source 2 0s to 999s 5 T27 Automatic configuration 0s to 999s 3 T02 min U source 1 0s to 999s 5 T28 Min critical U source 1 0s to 999s 1 T03 max U source 1 0s to 999s 5 T29 Max critical U source 1 0s to 999s 1 T04 min U ...

Page 7: ...ening of source 2 F06 2 OK source 2 OK F10 IN 1 Input 1 reporting F03 1 Closure of source 1 F07 AUTO NOK mode AUTO not OK F11 IN 2 Input 2 reporting F04 2 Closure of source 2 F08 2 T22 Request load shedding F12 IN 3 Input 3 reporting Programming inputs and outputs 1 Press OK 2 Press until you reach menu I O 3 Press OK 4 In the Input Output menu press or until you reach the desired input IN 1 IN 2 ...