85
y
Analyze among the automatically captured data which will be displayed or discarded then enter Pattern Setting.
- Unless you check “Auto” item, make sure to set up “Start Pattern” and “End Pattern”
- “Discard Pattern”, “Line Delimiter” and “MCPL” are utilized independently, not relation to “Auto” mode.
y
It is possible to input and analyze the serial data by clicking “Pattern” after tick the “Auto” box(
□
) off.
y
Each item explains below:
- Start Pattern : Indicates the beginning of the new data when new designated data are received from a
serial device.
- End Pattern : Indicates the end of the data when designated data are received from a serial device.
- Discard Pattern : Does not show the designated data on OSD screen. Sets up in order to designate
dummy data or characters which is not favorably to be displayed. Can be designated up
to 64 of discard patterns in total.
- Line Delimiter : Inputs characters to be used as delimiter between lines.
- MCPL(
M
inimum
C
haracter
P
er
L
ine) : Sets up the number of the minimum strings each line. Does not
show the characters on OSD screen if there is a character of which
number is below the designated number in each line divided by the
line delimiter.
Example)
y
When it firstly connected, the data will be displayed as below