XRGI® 20 COMMISSIONING INSTRUCTION
VERSION 1.0 2019
S Y S T E M PA R A M E T E R S
■
Move the cursor to the desired field by using the
▲▼
buttons and press
OK
on
the user interface to activate the field.
■
Enter the value by using the
▲▼
buttons and press
ESC
to save the entry.
System modus
: Select the desired operating mode.
Meter source
(only possible with powerled): Select the applied meter.
SYSTEM PARAMETERS
1/6
XRGI-ID:
XRGI type:
Max power:
Meter source:
Country:
System modus:
1234567890
XRGI 20
Powerled
Trafo
ENGLAND
20.1 kW
Send
Trafo type:
50/5
SYSTEM PARAMETERS
2/6
Power Unit no.:
Gas type:
1234567890
H
Trafo type
(only possible with meter source Trafo): Select the applied trafo type.
Land
: Select
ENGLAND
.
■
Go to the next page by using the
▲▼
buttons.
Power Unit no.
: Enter the Power Unit no. of the XRGI® system.
Gas type
:
Enter the type of gas used.
■
Go to the next page by using the
▲▼
buttons.
When installing a Load Sharer S, Modbus Gateway or VPP Gateway
please follow the installation instructions of the respective component.
FREQUENCY RESPONSE
6/6
Type:
G98:2018
FREQUENCY RESPONSE
6/6
Type:
Frequency treshold:
Droop setting:
Activation delay:
Reg. belov min load:
Return gradient:
Reference power:
50.40 Hz
Rated power
Continue
0.0 Sek
10 %
10.0 %
G98:2018
HEAT PUMPS
5/6
Heat pump 1:
0.5 kW
H E AT P U M P S
If heat pumps are connected to the system, enter the effect of the heat pumps.
■
Move the cursor to
Heat pumps
by using the
▲▼
buttons and press
OK
on the
user interface to activate the field.
■
Enter the effect of the heat pump by using the
▲▼
buttons and press
ESC
to
save the entry..
F R E Q U E N C Y R E S P O N S E
For the correct frequency response, set the standard of the country where the XRGI®
system is installed.
■
Move the cursor to
Type
by using the
▲▼
buttons and press
OK
on the user
interface to activate the field.
■
Select the correct frequency by using the
▲▼
buttons and press
ESC
to save the
entry.
COUNTRY
STANDARD
GERMANY
VDE 4105:2018
DENMARK
TB 27 04 2019
TF 3.2.1
TF 3.2.3
ENGLAND
G98:2018
G99:2018
ALL OTHER COUNTRIES
None
When selecting a standard, all values are automatically set for the applicable law. The
specified default values can be adjusted as required.
Summary of Contents for XRGI 6
Page 1: ...VERSION 1 0 2019 01DOC1075 01 COMMISSIONING INSTRUCTION...
Page 2: ......
Page 14: ...XRGI COMMISSIONING INSTRUCTION VERSION 1 0 2019 12...
Page 47: ...XRGI COMMISSIONING INSTRUCTION VERSION 1 0 2019 45 N OT E S...
Page 48: ...XRGI COMMISSIONING INSTRUCTION VERSION 1 0 2019 46 N OT I Z E N...
Page 49: ......
Page 50: ...01DOC1075 01 09 2019 CO M M I S S I O N I N G I N S T R U C T I O N...