CPX200NW ALARM CONTROL UNIT – USER MANUAL
6 / 28
EN
•
Possibility to review faults, alarm memories, event log
•
System/technical event history up to 5000 events
2.2.
ELECTRICAL CHARACTERISTIC
Supply voltage:
18VAC (16-20VAC)
Required transformer Power:
min. 20VA
Current consumption average/max:
(average measured@: fully charged battery,
established connection with server, connected
keypad, no sensors connected)
120mA / 1100mA @18VAC
Average current consumption; lack of
external supply (without keypad/ with
keypad):
(fully charged battery, no sensors connected,
established connection with server)
60mA / 80mA
Charging current:
(measured with totalny discharged battrey)
max. 350mA
Charging voltage:
13.8V
Supported bartery type:
Lead-acid 12V
Low voltage – event treshold:
11V
Voltage battery cut off level:
below 9V
Working temperature:
-10ºC to +55ºC
Working humidity:
5% to 93%
PCB dimensions:
152mm x 78mm x 30mm