CPX200NW ALARM CONTROL UNIT – USER MANUAL 

 

11 / 28 

 

EN 

5.

 

ARMING THE SYSTEM 

5.1.

 

ARMING THE SYSTEM 

5.1.1.

 

ARMING FROM KEYBOARD 

1.

 

Enter your code and press 

. 3 beeps will confirm the code.

 

 

Note:  If  incorrect  code  is  entered  the  keypad  will  emit  long 
constant  sound.  Repeat  the  arming  process  by  entering  the 
correct code. 

2.

 

Leave the facility before the time for leaving expires.  That state is indicated 
by intermittent sound and quick flashing the ARMED LED on the keypad until 
the  system  gets  fully  armed.  If  the  chirps  are  activated  the  arming  will  be 
confirmed by one chirp of siren. 

 

Note:  If  the  partition  is  not  plugged  to  any  zones,  the 
partition is not armed. 

5.1.2.

 

ARMING FROM REMOTE CONTROL 

Press  the  remote  control  buton  indicated  by  the  closed  padlock  symbol 

,

 

assigned  to  the  arming  function.  Keyboard  confirms  arming  by  lighting  ARMED 
LED.  If  the  chirps  are  activated  the  arming  will  be  confirmed  by  one  chirp  of 
siren. 
Note!  The  control  panel  allows  you  to  assign  remote  control  buttons  to  various 
functions. It is possibile to configure different arming button. 
 

5.2.

 

ARMING THE SYSTEM WITH FAULT 

If during the arming any faults are present in the system, the keypad will indicate it 
with flashing ARMED and SYSTEM LEDs and long constant audio signal. LEDs 1 to 8 
will indicate which system errors are present. That state will maintain for 10 seconds. 

If  there  is  no  possibility  to  quickly  remove  faults,  press 

  to  arm  the  system.  

Pressing 

 will cancel the arming process.  

 

Note: Remove the causes of faults as soon as possible.  

Error codes: 

1 – Damage or disruption of detector 

Summary of Contents for CPX200NW

Page 1: ...EN ALARM CONTROL UNIT CPX200NW User manual Version of the manual v1 5 Date of issue 2015 04 08 Firmware version 1 1 1 GPRS transmitter configurator version 1 3 45 23...

Page 2: ...content of the document is presented as is The present document shall not be deemed to be providing any warranties either express or implicit including but not limited to any implied warranties of me...

Page 3: ...SYSTEM WITH FAULT 11 6 DISARMING THE SYSTEM 13 6 1 DISARMING THE SYSTEM 13 6 1 1 DISARMING FROM THE KEYBOARD 13 6 1 2 DISARMING FROM THE REMOTE CONTROL 13 6 2 ALARM DISPLAY 13 6 3 ALARM MUTE 13 7 PART...

Page 4: ...acilities The central unit is equipped with 3 outputs and 7 wired and 9 wireless zones with the possibility to be divided into 2 partitions Dedicated KP16 LED keypad was designed in a modern discreet...

Page 5: ...ions with the possibility to assign any number of zones to each of them KEYBOARD cooperation with LED keyboard KP16 ability to connect up to three keypads TRANSMISSION Transmission of signals through...

Page 6: ...ection with server connected keypad no sensors connected 120mA 1100mA 18VAC Average current consumption lack of external supply without keypad with keypad fully charged battery no sensors connected es...

Page 7: ...ION Power supply voltage 10 13 8 VDC Power consumption typ 20 mA max 80 mA Keypad weight 70 g Size of casing 99 x 82 x 19 mm Keypad type LED 16 status LEDs 4 mode LEDs ALARM ARMED SYSTEM PROG Button l...

Page 8: ...ellow Flashing light means that in the control unit s memory there are faults that has already ceased there was power loss but it has already restored Constant light there is a fault in the system tha...

Page 9: ...t slightly in indicated hole and perform slight lever movement toward the rear side of the casing 11 Anti Sabotage Switch After the keypad is assembled the switch contact is closed Unauthorised disass...

Page 10: ...OL UNIT USER MANUAL 10 28 EN 4 REMOTE CONTROL SPECIFICATION Frequency 433 92MHz Coding Keeloq code hopping Number of buttons 4 Battery Varta Li Mn 3V type CR2032 ARM button DISARM button SILENT ALARM...

Page 11: ...TROL Press the remote control buton indicated by the closed padlock symbol assigned to the arming function Keyboard confirms arming by lighting ARMED LED If the chirps are activated the arming will be...

Page 12: ...ARM CONTROL UNIT USER MANUAL 12 28 EN 2 Damage of signalling device or signalling device active 3 Damage of internal connection or sabotage 4 AC power supply damage 5 Battery damage 6 ATS damage 8 Oth...

Page 13: ...ant sound Enter the correct code immediately and press 6 1 2 DISARMING FROM THE REMOTE CONTROL Press the remote control buton indicated by the open padlock assigned to the disarming function Keyboard...

Page 14: ...the entered changes press 4 If partition arming was selected the keypad will indicate counting the time for leaving the facility Leave the facility before the time for leaving expires After it is arm...

Page 15: ...otage of lines 1 to 16 If no diodes are on and the ALARM led is blinking then there alarms that were triggered by the source other than input lines Other alarms history can be accessed by selecting fo...

Page 16: ...ion about sabotage of zones press button 1 Sabotage of zone 1 2 Sabotage of zone 2 16 Sabotage of zone 16 To return to the main fault menu press 2 Fault of outputs 1 3 To display more detailed informa...

Page 17: ...t that fact with quickly flashing LED marked with the number of the blocked zone Zone blocking 1 Enter the number of the function and confirm with Enter the user code and press 3 tone beep will confir...

Page 18: ...o 7 digits and press to confirm 7 Enter the code of a newly added user again and press to finish adding or to exit without saving changes 8 Successful adding a new user will be confirmed with 3 beeps...

Page 19: ...be changed by the administrator only 3 beeps will confirm the successfully entered function Default admin code 1111 Administrator code hh mm where Administrator code Administrator code hh Hours mm Min...

Page 20: ...essages get expired and are deleted Message should contain only characters from English alphabet Furthermore if the text contains any spaces content of the message starting from the equation mark till...

Page 21: ...ds Room Feedback message SETNAME OK or SETNAME ERROR Feedback message description SETNAME OK command accepted SETNAME ERROR command rejected by the system Getting the name of partition Command syntax...

Page 22: ...essage SETTELNUM OK or SETTELNUM ERROR Feedback message description SETTELNUM OK command accepted SETTELNUM ERROR command rejected by the system Getting the phone number Command syntax XXXX GETTELNUM...

Page 23: ...r SETMESSAGE ERROR Feedback message description SETMESSAGE OK command accepted SETMESSAGE ERROR command rejected by the system Getting the content of text message Command syntax XXXX GETMESSAGE ID Com...

Page 24: ...Each digit counting from the left represents an index of the phone number first digit for the first phone number second digit for the second number and so on 0 message will not be send to this number...

Page 25: ...Feedback message GETUSERSMS EVENT TELNUM MSG_ID or GETUSERSMS EVENT ERROR Feedback message description GETUSERSMS EVENT TELNUM MSG_ID information about text message and phone number assinged to the ev...

Page 26: ...AMPEREND Fault of zones 1 3 ended POWER FAIL Power failure POWER OK Power failure ended BATTERY FAIL Battery failure BATTERY OK Battery failure ended AUX1 FAIL Failure of auxiliary output 1 AUX2 FAIL...

Page 27: ...CTOR8 PWR to DETECTOR16 PWR Detector 8 16 battery low DETECTOR8 PWROK to DETECTOR16 PWROK Detector 8 16 battery restored List of errors sent as feedback messages Alias name Description ERROR PERMISSIO...

Page 28: ...0 Added sms handling 23 01 2014 i1 1 1 0 Added info about remote commands and parameters configurable by sms 04 06 2014 i1 2 1 0rc12 Added chirp functionality 12 08 2014 i1 3 1 0rc16 Added 24h fire z...

Reviews: