CPX200NB ALARM CONTROL UNIT – INSTALLER MANUAL
18 / 116
3.6.2.
Keypad specification
Power supply voltage:
10 – 13.8 VDC
Power consumption:
typ. 20 mA, max. 70 mA
Keypad weight:
70 g
Size of casing:
99 x 82 x 19 mm
Keypad type:
LED, 16 status LEDs, 4 mode LEDs (ALARM, ARMED,
SYSTEM, PROG)
Button layout:
Standard telephone keypad 3 x 4 buttons
3.6.3.
Keypad installation
1.
KP16 keypad is intended for inside installation, on dry and even surface. Usually, it
is installed on wall, near the entrance door, 120-140 cm high from the ground.
2.
To open the keypad casing – insert a flat screwdriver in the bottom part of the
casing and press the latch. Then carefully take both parts of the casing apart,
starting from the casing’s bottom.
3.
Mark and drill holes in the wall to install the rear part of the casing.
4.
Screw the rear part of the casing to the wall. The attached 4 screws with dowels
are designed for concrete base. For other substrates should choose the
appropriate screws indywidually.
5.
Connect cables joining the keypad with the alarm control unit. Keypad terminals
marked: KT, KR, KP, KG shall be connected with KT, KR, KP, KG terminals in the
alarm control unit (see drg. 2.)
6.
Assembly the rear part of the casing with the front one starting from the casing’s
top. Make sure that the keypad is well assembled and sabotage switch is pressed
in.
3.6.4.
Addressing devices connected to the keypad bus
Each keypad to be connected to the bus must have its own individual address from the 1
to 3 range. Addresses must not repeat (the control panel does not suport devices having
identical addresses). It is recommended that consecutive addresses be assigned starting
from 1. In keypads, the address is set by software means. By default, address 1 is set.
Programing keypad address:
1.
Remove the keypad from the wall (tamper switch should be open).
2.
At the same time, press and hold the
and
,
or
, which
means a new keypad address.
3.
After about 5 seconds the keypad will display the programmed keypad address.
4.
After programming the keypad address, reset the control panel CPX200NB.