CPX200NB ALARM CONTROL UNIT – INSTALLER MANUAL
54 / 116
7.4.
DEVICE PROGRAMMING
In order to program the equipment, first you have to establish a connection with the
equipment. Depending on the connection mode two programming methods are available.
7.4.1.
Local programming
For local programming of the equipment, you should:
In PROG mode connect GD-PROG service cable between CONF connector (on device’s
PCB) and computer’s COM port, defined in Connections -> RS-232 option.
Connect the power supply to the alarm control unit. Upon connecting the power
supply and detecting the programming cable, the module will indicate it with LEDs:
the green one will go on and the red one will flash quickly.
Start the configuration wizard and define the options of the equipment (please refer
to chapter 8).
NOTE: Enter correct PIN code for used SIM card.
Select Send function. The window will appear where you have to select the previously
defined local connection (chapter 6.3.1.5.1). Copy the settings into the memory of
the equipment.
Switch the power off and disconnect the programming cable or switch the
programming device into DEBUG mode.
Insert SIM card.
Re-connect the power supply.
The equipment is ready for operation.
7.4.2.
Remote programming
Remote programming of the equipment is possible in two cases:
User has a configuration wizard of GPRS transmitters and computer-connected GSM
modem.
User works based on the receiver of OSM.Server monitoring system.
In the first case remote programming is carried out via CSD channel and the procedure is
the same as for local programming, with the only difference that in the options of a
connection the “GSM modem” shall be selected (please refer to chapter 6.3.1.5.2 – CSD
connection.
NOTE: Remote configuration via CSD channel is available only in
case the CSD data transfer is active for both SIM card inserted in
the equipment and SIM card installed in GSM modem.
In the second case, in accordance with chapter 6.3.1.5.2 - GPRS connection, you shall
define remote connection based on OSM.Server parameters. Since OSM.Server receives
(and sends) information only from equipment that is registered in its database, the first
operation you have to do for remote programming it to properly register the equipment.
The procedure is described in OSM.Server user manual.