Q3
PL
27
www.eberg.eu
indicator light is on in the LED
display.
Quick setting
1. When LED 1-7 is flashing, use
the "+" or "-" buttons and press OK
to select and confirm the day from
Monday to Sunday for which you
want to program the operating
time. The unselected day will have
default settings (start: "00", stop:
"00" - no work). The start and end
time of work on the 7th day must
be set (if the device is to be turned
off on the 7th day (Sunday), set
start: "00", stop: "00", then press
OK). The weekly work program will
be activated.
2. P6 has the function of saving the
weekly timer settings (switching
off the weekly timer function does
not erase the settings made in
program 6). The settings made in
program 6 are deleted when the
device is disconnected from the
power supply.
Disabling
the weekly
timer
Press the button
the seventh time to turn off
the weekly timer.
Description
of the LED
display
• When the settings have been entered, the LED
display shows the ambient temperature, the
indicator of the weekly timer and the indicators of
active functions.
• In heating mode (heating in 1st gear or heating
in 2nd gear, not in set temperature mode), after
selecting one of the programs:
- the display shows the ambient temperature and
the indicator of the weekly programmer lights up
constantly when it is the time for which the heating
is programmed.
- the display shows the ambient temperature and the
timer lamp blinks when it is the time in which no
heating is programmed.
• In the set temperature mode, after selecting one of
the programs:
- The display shows the ambient temperature,
the indicator of the weekly timer and the set
temperature mode constantly light up when it is
the time for which the heating is programmed.
- The display shows the ambient temperature, the