44
Room and floor thermostat
– The
built-in sensors regulate the room
temperature and the sensor in the floor
functions as a floor temperature limiter.
The limitation can be set to between
5°C and 45°C. The factory setting of
35°C gives a surface temperature of
approx. 27°C. The cut-out temperature
can be changed, see the section
How to
set the thermostat/Temperature
.
Important
In rooms with large windows that are
exposed to solar insolation, we recommend
the function
Room and floor thermostat
.
In rooms with wooden flooring, the function
Room and floor thermostat
must always be
used.