EBARA WINNER Operating And Maintenance Manual Download Page 4

4

EN

OPERATING AND MAINTENANCE MANUAL PART 2

THE USER SHOULD KEEP THIS DOCUMENT

1. INTRODUCTION

This instruction manual is split into two booklets: PART 1, 

containing general information regarding our whole product 

range;  and  PART  2,  containing  information  specific  to  the 

motor-driven  pump  you  have  purchased.  The  two  publica

-

tions are complementary to each other, so make sure you 

have both.

Comply with the instructions contained in them to get the 

most out of your motor-driven pump and assure its proper 

operation. If you need further information, get in touch with 

your nearest authorized dealer.

If information in the two parts contradict each other, take 

PART  2  containing  the  product’s  specific  information  as 

valid.

NO PART OF THESE ILLUSTRATIONS AND/OR TEXT MAY BE 

REPRODUCED FOR ANY REASON. 

The following symbols have been used in the compilation of 

this instruction booklet.

WARNING

Risk of damaging the pump or system

Risk of causing injury or damaging property

Electrical hazard

2. CONTENTS

1.  INTRODUCTION 

page 4 

2.  CONTENTS 

page 4

3. 

DESCRIPTION AND USE OF MOTOR-DRIVEN PUMP

 page 4

4.  SPECIFICATIONS 

page 4

5.  PREPARING FOR USE 

page 5

6.  TECHNICAL LITERATURE  

page 38

3. DESCRIPTION AND USE OF MOTOR-DRIVEN PUMP

3.1. DESCRIPTION

Description:

SUBMERSIBLE CENTRIFUGAL 

MOTORDRIVEN PUMPS

Model:

WINNER - 4WN

3.2. USE FOR WHICH PUMPS ARE DESIGNED

The  pumps  can  be  used  for  lifting  and  distributing  clean 

water or water with a sand content not exceeding the limit 

given in chap. 4.

The submersible motor-driven pumps are used:

–  for industrial water supply systems;

–  Pressure boosting systems;

–   Medium-capacity sprinkler systems for fire fighting;

–  jet or flood irrigation systems;

–  for any applications involving drawing water from a well.

Use the motor-driven pumps based on their technical speci

-

fications.

3.3. USE FOR WHICH PUMPS ARE NOT DESIGNED

The submersible motor-driven pumps must not be made to 

work without water. 

If there is any chance of the waterbed 

lowering to a point where the pump will be exposed, you will 

need to install a minimum-level sensor as a safety measure.

4. SPECIFICATIONS

WINNER-4WN series pumps come in versions with a water-

bath motor (WY) or Marcol 82 oil-bath motor (OY) and the 

nonreturn valve is built into the pump;
4.1. PUMP SPECIFICATIONS

U.M.

WINNER

4WN

Max. temperature of liquid 

pumped 

°C

40

Max. amount 

of sand in suspension

g/m

3

50

Max. size 

of solids

mm

-

Type of liquid pumped

Clean water

4.2. WATER-BATH MOTOR SPECIFICATIONS: WY

Pump

WINNER

Max. temperature of 

liquid pumped 

°C

35 Sumoto

30 Franklin

Insulation class

B Franklin

F Sumoto

IP rating

IP

68

Type of duty

Continuo S1

Maximum immersion

m

150 Sumoto

350 Franklin

Max. starts per hour

n.°

30 Sumoto

20 Franklin

4.3. OIL-BATH MOTOR SPECIFICATIONS: OY

Pump

WINNER

4WN

Max. temperature 

of liquid pumped 

°C

35

Insulation class

F

IP rating

IP

68

Type of duty

Continuo S1

Maximum immersion m

150

Max. starts 

per hour

n.°

30

4.4. RATING PLATES

The manufacturer reserves the right to make changes.

Summary of Contents for WINNER

Page 1: ...sanvisninger OVERS TTELSE AF DEN ORIGINALE BRUGSANVISNING 14 UPPOPUMPPU WINNER 4 4WN 4 K ytt ja huolto ohjeosa 2 K NN S ALKUPER ISEST OHJEET 16 ELEKTRISCHE CENTRIFUGALE DOMPELPOMP WINNER 4 4WN 4 Instr...

Page 2: ...e di ac qua pulita o con quantit di sabbia non superiori a quanto riportato nel cap 4 Le elettropompe sommerse sono impiegate per impianti di alimentazione idrica nell uso industriale Impianti di pres...

Page 3: ...esegue anche contemporaneamente il prolunga mento del tubo di mandata modulare interponendo delle valvole di ritegno dove necessario il tubo di mandata deve avere lo stesso diametro o maggiore della b...

Page 4: ...d distributing clean water or water with a sand content not exceeding the limit given in chap 4 The submersible motor driven pumps are used for industrial water supply systems Pressure boosting system...

Page 5: ...lar delivery pipe is performed at the same time as the pump is lowered into the well by means of the safety cable This involves inserting non return valves between the parts where necessary the delive...

Page 6: ...port au chap 4 Les lectropompes immerg es sont utilis es pour les syst mes d alimentation hydrique qu il s agisse d un usage industriel les syst mes de pressurisation les syst mes de lutte contre les...

Page 7: ...dans le puits l aide du c ble rallonger galement le tuyau de refoulement modulaire en pla ant des soupapes de retenue l o c est n cessaire le tuyau de refoulement doit avoir un diam tre gal ou sup rie...

Page 8: ...oder Wasser mit einem Sandanteil verwendet der die Anga ben in Kapitel 4 nicht bersteigt Die Tauch Elektropumpen werden eingesetzt in Wasserleitungsanlagen in Industrie in Druckverdichtungsanlagen in...

Page 9: ...r Pumpe in den Schacht mit dem Seil wird auch eine vor bergehende Verl ngerung der modularen Auslassleitung durch Zwischenschaltung von R ckschlag ventilen vorgenommen wo dies erforderlich ist der Dur...

Page 10: ...con una cantidad de arena no superior a lo indicado en el cap 4 Las electrobombas sumergidas se utilizan para para instalaciones de alimentaci n h drica para empleo industrial instalaciones de presur...

Page 11: ...la bomba en el pozo a trav s de la cuerda se realiza tambi n contempor neamente la prolongaci n del tubo modular de impulsi n colocando v lvulas de re tenci n donde sea necesario el tubo de impulsi n...

Page 12: ...det som anges i kapitel 4 De neds nkta elpumparna anv nds f r hydraulsystem industribruk tryckanl ggningar brandsl ckningssystem med genomsnittlig kapacitet sm och medelstora bevattningar med str le e...

Page 13: ...nslutningarna r korrekta e d pumpen s nks ner i brunnen med hj lp av linor ska man samtidigt g ra f rl ngningen av matarslangen genom att montera strypventiler d r det beh vs matar slangen ska ha samm...

Page 14: ...vand eller af vand med et sandindhold der ikke oversti ger anvisningerne i kap 4 De nedsunkne elektropumpers brugsomr der vandforsyningsanl g til industrielt brug Trykoparbejdningsanl g Mellemstore sl...

Page 15: ...er udf rt korrekt e mens pumpen s nkes ned i br nden ved hj lp af re bet udf res samtidig forl ngelsen af den modul re afledningsr rledning idet der inds ttes kontraventiler efter behov afledningssla...

Page 16: ...eollisuuslaitosten vesihuolto painelaitokset keskikokoiset sammutuslaitteistot sadetus ja tulvituslaitteistot kaikki k ytt kohteet joissa vett nostetaan kaivoista S hk pumppujen k yt ss on huomioitava...

Page 17: ...n k yden avulla samalla pidennet n painepuolen modulaarista putkea ja asen netaan siihen tarvittaessa vastaventtiilej painepuolen putken l pimitan on oltava sama tai suurempi kuin s h k pumpun aukon V...

Page 18: ...in hoeveelhe den kleiner dan die aangegeven in hfdst 4 De elektrische dompelpompen worden gebruikt voor watervoorzieningsinstallaties en industrieel gebruik systemen voor drukregeling blusinrichtinge...

Page 19: ...p in de put wordt neergelaten met be hulp van de kabel wordt tegelijkertijd de verlenging van de modulaire persleiding uitgevoerd door terugslagklep pen in te voegen waar noodzakelijk de persleiding m...

Page 20: ...n o superiores ao indi cado no cap 4 As electrobombas submers veis s o utilizadas para Instala es de alimenta o h drica no uso industrial instala es de pressuriza o Instala es anti inc ndio de m dio c...

Page 21: ...bomba no po o com aux lio do cabo executa se simultaneamente a extens o do tubo de des carga modular colocando v lvulas de reten o onde necess rio o tubo de descarga deve ter di metro igual ou superi...

Page 22: ...4WN 3 2 4 3 3 4 WINNER 4WN WY OY Marcol 82 4 1 U M WINNER 4WN C 40 g m3 50 mm 4 2 WY WINNER C 35 Sumoto 30 Franklin B Franklin F Sumoto IP 68 Continuo S1 m 150 Sumoto 350 Franklin n 30 Sumoto 20 Fran...

Page 23: ...23 GR 4 4 1 WINNER 4WN WINNER 4WN 1 12 4 5 70 dB A 5 XH WINNER 4WN 7 1 5 1 WINNER 4WN WINNER 4WN NEMA 5 1 1 a 1 b c d e f 15 m 40 m g 1m 1 m h 0 10 m s 5 1 2 7 8 1 7 8 5 2 1...

Page 24: ...p 4 Elektrick ponorn erpadla se pou vaj pro za zen rozvodu vody pro pr myslov vyu it za zen na zvy ov n tlaku protipo rn za zen st edn velikosti povrchov zavla ov n a zavla ov n post ikem st edn ch pl...

Page 25: ...n a spoj e spus te erpadlo do vrtu pomoc lana sou asn instalujte tak modul rn prodlu ku v tla n hadice na kterou na pot ebn ch m stech instalujte zp tn klapky v tla n hadice mus m t stejn nebo v t pr...

Page 26: ...sku ktor neprevy uje hodnoty uveden v kap 4 Elektrick erpadla s pou van na zariadenia rozvodu vody pre priemyseln ely tlakov zariadenia protipo iarne zariadenia strednej ve kosti zavla ovacie zariaden...

Page 27: ...dla do studne pomocou lana sa s asne predl uje modul rna pr vodn hadica do ktorej sa v ur it ch intervaloch do potrebn ch miest in taluje sp tn ventil pr vodn hadica mus ma rovnak alebo v priemer ako...

Page 28: ...ktryczne pompy zanurzeniowe s u ywane w urz dzeniach zasilaj cych wod do u ytku przemys owego urz dzeniach ci nieniowych urz dzeniach przeciwpo arowych o redniej wydajno ci nawodnieniach strumieniem l...

Page 29: ...e opu ci pomp do studni za pomoc linki wykonuj c jednocze nie modu owe przed u enie rury t ocz cej montuj c zawory zwrotne w miejscach gdzie to niezb dne rura t ocz ca musi mie tak sam lub wi ksz red...

Page 30: ...3 1 WINNER 4WN 3 2 4 3 3 4 WINNER 4WN WY OY Marcol 82 4 1 WINNER 4WN C 40 3 50 4 2 WY WINNER C 35 Sumoto 30 Franklin B Franklin F Sumoto IP 68 Continuo S1 150 Sumoto 350 Franklin n 30 Sumoto 20 Frankl...

Page 31: ...31 RU 4 4 1 WINNER 4WN WINNER 4WN 1 12 4 5 70 A 5 BH MAH E WINNER 4WN 1 7 5 1 WINNER 4WN WINNER 4WN NEMA 5 1 1 a 1 b c d e f 15 40 g 1 1 h 0 10 5 1 2 7 8 1 7 8 5 2 1...

Page 32: ...ea apei curate sau cu o cantitate de nisip care nu este superioar celor indicate n cap 4 Electropompele submersibile sunt folosite pentru instala ii de alimentare hidric de uz industrial Instala ii de...

Page 33: ...nexiunile sunt bine f cute e cobor nd pompa n pu prin intermediul funiei se execut n acela i timp prelungirea evii de tur modu lare interpun nd valve de re inere unde este necesar eava de tur trebuie...

Page 34: ...irler Dalg elektro pompalar a a da belirtilen do rultuda kullan labilir sanayi su besleme tesisleri i in bas n land rma tesisleri Orta l ekli yang n s nd rme tesisleri p sk rtme ve zirai sulamalar nda...

Page 35: ...ediniz e pompay kuyuya indirirken halat arac l ile ayn anda gereken yerde kapatma vanalar n da araya yerle tirerek mod ler besleme borusunun uzant s uygulan r besleme borusu elektro pompa a z ile ayn...

Page 36: ...36...

Page 37: ...37...

Page 38: ...HE DOKUMENTATION 6 DOCUMENTACI N T CNICA 6 TEKNISK DOKUMENTATION 6 TEKNISK DOKUMENTATION 6 TEKNISET ASIAKIRJAT 6 TECHNISCHE DOCUMENTATIE 6 DOCUMENTA O T CNICA 6 6 TECHNICK DOKUMENTACE 6 TECHNICK DOKUM...

Page 39: ...Geel groen 1 Amarelo Verde 1 1 luto zelen 2 Sort 2 Musta 2 Zwart 2 Preto 2 2 ern 3 Bl 3 Sininen 3 Blauw 3 Azul escuro 3 3 Modr 4 Brun 4 Ruskea 4 Bruin 4 Castanho 4 4 Hn d 5 Kabelklemme 5 Johdonkiristi...

Page 40: ...750 5 5 7 5 32 48 80 128 I GB F D E Esempio motore 1 1 kW monofase 220V Lunghezza cavo 39m Seguendo la tabella la scelta cade su sez cavo 4x2 5mm2 Example motor 1 1 kW single phase 220V Cable length 3...

Page 41: ...rre effektspredning og en st rre kabelophedning On t rke k ytt kaapelia jossa on sopiva profiili jotta saavutetaan s h k pumpun hyv toiminta P t taulukon avulla kaapelin profiili suhteessa sen pituute...

Page 42: ...us productoselectrobombasWINNERy4WNsoncumplenconlasdisposiciones establecidas en las siguientes directivas europeas Directiva M quinas 2006 42 CE Directiva Baja Tensi n 2006 95 CE Directiva Compatibil...

Page 43: ...Identifika n t tok elektricka cerpadlo Tabliczka znamionowa z danymi technicznymi pompy elektryczne Placa de date electropomp Plaka verileri elektropompalar Targa dati motore Name plate motor Plaque...

Page 44: ...el 48 22 3909920 Fax 48 22 3909929 e mail mktgpl ebaraeurope com EBARA Pumps Europe S p A GERMANY Elisabeth Selbert Stra e 2 63110 Rodgau Germany Tel 49 0 6106 66099 0 Fax 49 0 6106 66099 45 e mail mk...

Reviews: