P.24
PM10U
EBARA
CORPORATION
CAUTION
Do not wire vacant pins.
CAUTION
Apply a 12V DC power for input signals on the pump side.
Do not apply this voltage on the equipment side.
The output signals are generated from an open collector
output.
Please use it by the equipment side, impressing the power
supply of DC4V to DC27V.
CAUTION
Be sure to wire all signals with the correct polarity(SIG./COM.)
CAUTION
When output signals are used to energize an inductive load
such as a relay, be sure to insert a diode (100V. 1A class) in
order to absorb the back electromotive force due to surge
currents.
5. Power Supply for accessories
Power supply connector for accessory is equipped beside main power supply
connector. This power supply is used for standard option that is listed below.
(Shall not be used for other purposes.)
ADAPTER for Central Monitoring System
Interface Controller
N2 Solenoid Valve
DANGER
Power Supply for the options is kept applying voltage when
Earth Leakage Breaker (ELB) turns on during the pump is
supplied the power.
WARNING
Do not use the power supply for other purposes.