background image

1

1

2

2

3

3

4

4

5

5

6

6

A

A

B

B

C

C

D

D

DIMENSIONS IN m.m.

OTHERWISE STATED

ANGULAR 

TOLERANCES UNLESS

0.0     

IF IN DOUBT ASK

DO NOT SCALE

0.00    

3RD ANGLE PROJECTION

1993

0.      

0.25

0.5 DEGREE

0.05

TITLE

MATERIAL

FINISH

BISHOP AUCKLAND
ENGLAND

LIMITED

SHEET

DRAWN :

CAD SCALE :

DRG.NO.

OF

1

CS60 GENERAL ASSEMBLY

VARIOUS

 

10264CS-US

C LILLY

1/4

1

1

1

1

Base

2

1

Left Base Support

3

1

Right Base Support 

4

1

Drain Pipe

5

1

Condenser

6

1

Evaporator Coil

7

1

Fan Housing

8

4

Rubber Foot

9

1

Fan Inlet Ring

10

1

Fan Motor

11

1

Fan Blade

12

1

Electrical Box

13

1

Capacitor

14

1

Timer

15

1

Relay

16

1

Solenoid Coil

17

1

Solenoid Valve

18

1

Humidistat

19

1

Compressor

20

1

Cover

21

1

Handle

22

1

Handle Support

Parts List

ITEM

QTY

DESCRIPTION

ISS.

DATE

COMMENTS

1

12/07/04

ORIGINAL

3

12

14

15

13

6

5

8

2

1

10

11

9

19

17

16

7

20

22

21

18

4

Summary of Contents for CS60

Page 1: ...CS60 OWNERS MANUAL Drawing No TPC302 Issue 1 Date 12 07 04 EBAC MODEL CS60 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL...

Page 2: ...quipped with a permanent drain The cooled air then passes through the hot condenser coil where it is reheated using the same energy removed during the cooling phase plus the additional heat generated...

Page 3: ...TIONS MODEL CS60 HEIGHT 13 25 336 55mm WIDTH 13 75 349 25mm DEPTH 20 25 514 35mm WEIGHT 62 83lbs 28 5 kg AIRFLOW 360 CFM EXTRACTION 56 Pints Per Day At 80 F 60 RH POWER SUPPLY 115V 60Hz 1 ph FINISH Po...

Page 4: ...eave the machine running for 15 minutes E Observe the evaporator coils through the rear upper grill to confirm frost operation i If the air temperature is below 80 F an even coating of frost should co...

Page 5: ...ore does not need oiling 3 To check the refrigerant charge run the unit for 15 minutes and briefly remove the top cover The evaporator coil should be evenly frost coated across its surface At temperat...

Page 6: ...of the refrigerant compressor The charging stub should be crimped and rebrazed after servicing NEVER allow permanent service valves to be fitted to any part of the circuit Service valves may leak cau...

Page 7: ...s of refrigerant gas 1 Check all of the above 2 Contact the Factory Service Center 3 Contact the Factory Service Center Little or no defrost when required 1 Faulty timer 2 Faulty by pass valve 1 Conta...

Page 8: ...noid Valve 3020814 1 5 Filter Dryer 3020901 1 6 Compressor 3022163 1 7 Solenoid Coil 3030421 1 8 Capacitor 3030908 1 9 Humidistat 3035145 1 10 Mains Lead 3035148 1 11 Fan Motor 3035788 1 12 Relay 3036...

Page 9: ...H OF ANY WRITTEN OR IMPLIED WARRANTY WITH RESPECT TO THE FOREGOING DESCRIBED MERCHANDISE For Your Records Model ____________________ S N ______________________ Date Received ______________ SAVE THIS S...

Page 10: ......

Page 11: ......

Page 12: ...0264CS US C LILLY 1 4 1 1 1 1 Base 2 1 Left Base Support 3 1 Right Base Support 4 1 Drain Pipe 5 1 Condenser 6 1 Evaporator Coil 7 1 Fan Housing 8 4 Rubber Foot 9 1 Fan Inlet Ring 10 1 Fan Motor 11 1...

Reviews: