6 Operation
6.3 Switching off the device
56
MICRO PANEL XV400 5.7"/8.4"
12/2014 MN04802009Z-EN
www.eaton.com
6.3
Switching off the device
1
De-energize the device.
CAUTION
Data loss
During a write operation, the CF card may lose data or may be destroyed if it is re-
moved or if there is a power failure.
Always secure CF cards with the CF slot cover.
Avoid write operations to CF cards. Reasons:
-
The number of write cycles possible on CF cards is limited.
-
A power failure during write operations will most likely lead to loss of data.
Only remove the CF card when the device is in a de-energized state.
Before switching off, ensure that no software write operations to the CF card are
in progress («CF ACT» LED must not be lit).
Frequent on/off switching of the device, especially at low temperatures, will reduce the
lifespan of the cold cathode tubes (CCFL) of the backlight.
Avoid frequent on/off switching of the device.
Reduce the brightness of the backlight instead (