![Eaton VICKERS SystemStak Manual Download Page 7](http://html1.mh-extra.com/html/eaton/vickers-systemstak/vickers-systemstak_manual_4149130007.webp)
Installation Dimensions in mm (inches)
DGMC(2)-3**-**(-B*-**)-4*
Models with type W adjuster
To adjust valve setting slacken off locknut
and turn adjuster screw .
Turn clockwise to increase pressure;
counter-clockwise to decrease pressure
Re-tighten locknut after completing
adjustment.
For gage port thread options see model code
A
P
B
T
A
P
B
T
A max.
79 (3.1)
fully out
Line B or line P adjustment
(according to model type)
Line A adjustment
B max.
4 (0.16) max. over gage port plug
4 (
5
/
32
) A/F hex. socket
40
(1.57)
3,5 (0.14)
Ø
3 (0.12 dia)
20
(0.79)
47,6
(1.87)
46
(1.8)
39 (1.54)
76 (3)
C max.
D max.
4 off
“
O
”
seals supplied for this mounting face
4 holes through:
Ø
5,3 (0.21 dia)
12,7 (
1
/
2
) A/F hex. locknut
Torque to 25-30 Nm (18-22 lbf ft)
8
Model
A
B
C
D
DGMC-3-AT-*W-4*
–
–
154 (6.1)
–
DGMC-3-BT-*W-4*
–
–
–
156 (6.2)
DGMC-3-AT-*W-*-4*
–
160 (6.3)
–
–
DGMC-3-PT-*W-4*
–
–
–
156 (6.2)
DGMC-3-PT-*W-*-4*
–
160 (6.3)
–
–
DGMC2-3-AT-*W-BT-*W-4*
234 (9.2)
–
–
–
7