![Eaton VICKERS SystemStak Manual Download Page 37](http://html1.mh-extra.com/html/eaton/vickers-systemstak/vickers-systemstak_manual_4149130037.webp)
12
Eaton Vickers
Solenoid Operated Directional Valves
Product Catalog V-VLDI-MC011-E September 2008
Single solenoid models
s
DG4V-3(S)-*A(-**)
n
DG4V-3(S)-*B(-**)
n
DG4V-3(S)-8BL(-**)
DG3V-3(S)-*F
n
Installation
Dimensions
Models for use with ISO 4400 (DIN 43650) connectors
Double solenoid models
s
DG4V-3(S)-*C-**-(V)M-U-**-60
DG4V-3(S)-*N-**-(V)M-U-**-60
DG4V-3(S)-*AL(-**)
n
DG4V-3(S)-*BL(-**)
n
DG4V-3(S)-8B(-**)
DG4V-3(S)-*FL(-**)
n
3rd angle
projection
n
Not applicable to type “8” spool.
s
See page 25 for solenoid information.
‡ Can vary dependent on source of plug.
Model type
AC or DC A Dim.
B Dim.
C Dim.
D Dim.
All
DC =
220 (8.66) 156 (6.14) 61 (2.5) 73 (2.87)
DG4V-3
AC ~
200 (7.87) 146 (5.75) 51 (2.1) 63 (2.48)
DG4V-3S
AC ~
200 (7.87) 146 (5.75) 45 (1.7) 63 (2.48)
Water-resistant manual override on solenoid
DG4V-3(S)-****(L)-H-(V)M-**-**-60
Application
General use where finger operation is required (standard manual
overrides cannot be operated without using small tool).
Note:
“H” feature is not field convertible from other models;
specify with order.
Latching manual override on solenoid
DG4V-3-****(L)-Y-(V)M-**-**-60
DG4V-3S-****(L)-Y-(V)M-**-**-60, DC coil models only
Application
Stainless steel lever/latch mechanism and water-resistant seal
make this feature ideal for vehicle-mounted and exposed
applications requiring emergency selection of valve for a period
of time in the event of electrical failure.
Notes:
1. Opposite solenoid (on “C” and “N” double solenoid models)
should not be energized while the valve is latched in selected
position; AC solenoid coils will burn out under
this improper usage.
2. “Y” feature is field-convertible from “H” type manual override
(omitting spacer), but is not field-convertible from other models.
As
shown
Spolenoid
and end cap
interchanged
24,00
(0.94)
Coil types: U (shown), KU, SP1,
and SP2 (see Model Code)
A (double solenoid model)
87,0
(3.42)
53,00
(2.1)
B (single solenoid model)
21,75
(0.86)
25,00
(0.98)
100,0
(4.0)
D
74,00
(2.91)
48,00
(1.88)
Alternative plug positions by
loosening knurled nut, turning
coil, and re-tightening.
Port A
Port P
Port T
Port B
C, coil
length
Spacer
15
(0.6)
Overall length of valve with
standard manual overrides
Overall length of
valve with standard
manual overrides
Lever in latched position
Lever in free position
Lift latch to
release lever
65
(2.5)
40
(1.6)
Manual
actucation must
be applied within
this diameter:
approximately
20(0.75).
Spacer prevents
actuation by
larger device.
Push lever to
operate valve;
latch holds lever in
operated position
Spacer
15
(0.6)
Overall length of valve with
standard manual overrides
Overall length of
valve with standard
manual overrides
Lever in latched position
Lever in free position
Lift latch to
release lever
65
(2.5)
40
(1.6)
Manual
actucation must
be applied within
this diameter:
approximately
20(0.75).
Spacer prevents
actuation by
larger device.
Push lever to
operate valve;
latch holds lever in
operated position
Dimensions in mm(in).