![Eaton VICKERS SystemStak Manual Download Page 32](http://html1.mh-extra.com/html/eaton/vickers-systemstak/vickers-systemstak_manual_4149130032.webp)
7
Eaton Vickers
Solenoid Operated Directional Valves
Product Catalog V-VLDI-MC011-E September 2008
Operating Data
Performance data is typical with fluid at 36cSt (168 SUS) and 50°C (122°F).
Standard pErFormancE ValVE HigH pErFormancE ValVE
FEaturE
dg4V-3S
dg4V-3
Pressure Limits
P, A and B ports
350 bar (5075 psi)
n
350 bar (5075 psi)
T port:
Spool indicator switch models
Types S3, S4, S5
N/A
10 bar (145 psi)
Type S6
N/A
210 bar (3045 psi)
All other models
100 bar (1450 psi)
210 bar (3045 psi)
Flow rating
See performance data
See performance data
Relative duty factor
Continuous; ED = 100%
Continuous; ED = 100%
Type of protection:
ISO 4400 coils with plug fitted correctly
IEC 144 class IP65
IEC 144 class IP65
SP1 – Single spade 6,3 mm
IEC 760
IEC 760
SP2 – Dual spade 6,3 mm
IEC 760
IEC 760
Coil winding
Class H
Class H
Lead wires (coils type F***)
Class H
Class H
Coil encapsulation
Class F
Class F
Permissable voltage fluctuation:
Maximum
Refer to temperature limits.
Refer to temperature limits.
Minimum
90% rated
90% rated
Typical response times at 100% rated volts measured from
application/removal of voltage to full spool displacement of “2C” spool at:
Flow rate P-A, B-T
20 l/min (5.3 USgpm)
40 l/min (10.6 USgpm)
Pressure
175 bar (2537 psi)
175 bar (2537 psi)
AC (~) energizing
18 ms
15 ms
AC (~) de–energizing
32 ms
23 ms
DC (=) energizing
60 ms
45 ms
DC (=) de–energizing
40 ms
28 ms
Power consumption, AC solenoids
Initial
s
Holding
Initial
s
Holding
(for coils listed in model code).
VA (RMS)
VA (RMS)
VA (RMS)
VA (RMS)
Full power coils:
Single frequency coils AC 50 Hz
225
39
265
54
Dual frequency coils at 50 Hz
265
49
280
61
Dual frequency coils at 60 HZ
260
48
300
58
Low power coils, “BL” and “DL”:
(Not available with “N” – No-spring detented models)
Low power coils not usable
170
37
Dual frequency coils at 50 Hz
with DG4V-3S valves.
190
37
Dual frequency coils at 60 Hz
Power consumption, DC solenoids at rated voltage and 20 C (68 F).
Full power coils:
12V, model type “G”
30W
–
30W
–
24V, model type “H”
30W
–
30W
–
Low power coils:
12V, model type “GL”
Low power coils not usable
18W
–
24V, model type “HL”
with DG4V-3S valves.
18W
–
n
For applications where valves are to remain pressurized (either energized or de-energized) at pressures over 210 bar (3045 psi)
without frequent switching, it is recommended to use the high performance model, DG4V-3.
s
1st half cycle; armature fully retracted.