% Factor
80
100
120
140
160
15
25
35
45
55
65
75
85
cSt
75 100
150
200
250
300
350
400
SUS
Viscosity
Pressure Drop at
Other Viscosities
Published pressure drop data is valid for
a fluid viscosity of 21 cSt (102 SUS).
The graph shows the approximate
percentage change in pressure drop for
a range of other viscosities. To
determine the approximate pressure
drop for any given fluid viscosity, multiply
the published data by the % factor for
the required viscosity.
Type H Adjuster
To adjust valve setting, slacken M4 locking
screw and rotate knob . Re-tighten locking screw
after completing adjustment.
Available on
DGMC-3
DGMR-3
DGMX-3
89 (3.5) max.
Ø
32 (1.26 dia)
M4 locking screw
2 (
5
/
64
) A/F hex. socket
Type K Adjuster
Key must be inserted and turned to allow valve to be
adjusted . When key is removed, adjustment
mechanism can be freely turned without changing
valve setting.
Available on
DGMC-3
DGMR-3
DGMX-3
Ø
32 (1.26 dia)
115 (4.5) max.
25
(1)
18 (0.71)
for key removal
Turn clockwise to increase pressure;
counter-clockwise to decrease pressure
Spare Parts
Valves are sold complete with all seals.
Part numbers for available spare seal
kits:
DGMC-3-40/41
870738
. . . . . . . . . . . . . .
DGMC2-3-40/41
870737
. . . . . . . . . . . . .
DGMR(1)-3-40/41
870739
. . . . . . . . . . .
DGMX(*)-3-40/41
870739
. . . . . . . . . . . .
DGMDC-3-40/41
870708
. . . . . . . . . . . .
DGMPC-3-40/41
870708
. . . . . . . . . . . .
DGMFN-3-40/41
870707
. . . . . . . . . . . . .
Note: Seal kits cover various model options for the
respective types. Redundant seals will be found for
some models.
Warranty and Repair
Units to be returned under warranty
should be sent, with a description of the
fault, to the Vickers representative in
your area.
Repair of these size 03 valves is not
generally economically viable. Contact
your nearest Vickers representative
before returning any unit for repair.
Ordering Procedure
Specify requirements by valve model
code, and by seal kit number.