![Eaton VICKERS SystemStak Manual Download Page 12](http://html1.mh-extra.com/html/eaton/vickers-systemstak/vickers-systemstak_manual_4149130012.webp)
DGMR-3-TA-**-*-4*
DGMR1-3-PP-**-*-4*
DGMX(*)-3-P*(L)-**-*-4*
Models with type W adjuster
To adjust valve setting slacken off locknut and turn
adjuster screw
Turn clockwise to increase pressure;
counter-clockwise to decrease pressure.
Re-tighten locknut after completing adjustment.
DGMX2-3-**
L
models have adjuster and end
cap/gage port locations interchanged from positions
shown.
Installation Dimensions in mm (inches)
A
P
B
T
A
P
B
T
14 (0.55) max.
4 (
5
/
32
) A/F hex. socket
40
(1.57)
3,5 (0.14)
Ø
3 (0.12 dia)
20
(0.79)
47,6
(1.87)
46
(1.8)
39 (1.54)
76 (3)
4 off
“
O
”
seals supplied for this mounting face
4 holes through:
Ø
5,3 (0.21 dia)
12,7 (
1
/
2
) A/F hex. locknut
Torque to 25-30 Nm (18-22 lbf ft)
80 (3,1) max.
For gage port thread options see model code ,
(pressure plug fitted)
6
12