Sonix 2Mx Technical Manual

SONIX 2MX TECHNICAL MANUAL  

TM370 / A  June 2022  www.eaton.com

9  Customisation

While every effort has been expended to make 

the standard Sonix PA/GA system configuration, 

this might not cover every requirement. To this end 

customisation of the 2Mx, and any part of the Sonix 

eco-system, should be discussed with your local Eaton 

representative. 

Certain features are considered as requiring 

customisation by default.

9.1  IO audio and zoning

Currently the zoning for the Sonix Io unit is held within 

the 2Mx firmware, please contact your local Eaton 

representative to discuss options. This includes BGM 

zoning.

9.2  Alarm Tones

Customisable alarm tones are possible, please contact 

your local Eaton representative to discuss options.

Due to the way alarm tone audio is generated within 

Sonix 350-d Amplifier, it is not possible to ‘mix’ multiple 

tones simultaneously. Similarly, Sonix is not able to 

provide volume adjustment to full volume alarm tones, 

except by utilising attenuated alarm.

9.3  Important message over Alarm volume

The volume of Alarm Tone that is mixed into the 

Emergency Speech broadcast is set to approximately 

12dB lower than the normal Attenuated Alarm. This 

value can be customised to one of the following: 1.1, 

2.5, 4, 6, 8.5, 12 or 18dB.

ote: 

N

Higher values limit the maximum level of Alarm Attenuate that 

can be used before the volume difference is lost.

 

9.4  Program fault

The program fault, or minor fault, is a signal generated 

from a sub-set of the available system faults and 

transmitted out of the PA/GA system via the Sonix Io 

unit.

The list of standard faults available is as follows:

• 

Amp Line fault

• 

Beacon Line fault *

• 

Amp Data Fault

• 

Hmi 1 Data Fault

• 

Hmi 2 Data Fault

• 

Beacon Data Fault *

• 

IO Data Fault

• 

Power Data Fault

• 

Sync Data Fault

• 

Global Data Fault

• 

Amp Audio Fault

• 

Hmi 1 Audio Fault

• 

Hmi 2 Audio Fault

• 

IO Audio Fault

• 

Sync Audio Fault

• 

Global Audio Fault

• 

Amp Equipment Fault

• 

Hmi Equipment Fault

• 

Beacon Equipment Fault *

• 

Power Equipment Fault

• 

IO Equipment Fault

• 

MS12 Equipment Fault

• 

Pbx-Tu Equipment Fault

• 

Matrix Fault

• 

Sync Equipment Fault

Items marked with a * comprise all available beacon 

faults and are considered standard output functionality. 

ote: 

N

This can be customised to support any combination of the listed 

faults, please contact your local Eaton representative to discuss.

Summary of Contents for SONIX 2Mx

Page 1: ...Alarms Important Message AUX OPERATIONAL Beacons System Reset Beacon Test Global Ticktone Global Sense Test LOCAL STATUS Matrix HMI Amplifier Beacon I O Power Dist Default Config Bgm 1 2 3 4 5 6 1 2 P...

Page 2: ...FOR A PARTICULAR PURPOSE OR MERCHANTABILITY OTHER THAN THOSE SPECIFICALLY SET OUT IN ANY EXISTING CONTRACT BETWEEN THE PARTIES ANY SUCH CONTRACT STATES THE ENTIRE OBLIGATION OF EATON THE CONTENTS OF T...

Page 3: ...feedback 2Mx Sonix 2Mx Central controller Amp 350 d Sonix 350 W Power Amplifier with 100 V line output Eol1 Sonix Remote End of Line unit Eol8 Sonix Amplifier to 100 V line interface unit 8 channel SP...

Page 4: ...Port Indicators 9 5 4 2 Bus connections 10 5 4 2 1 Split loop 10 5 4 3 Audio 10 5 4 4 Global bus 10 6 UNIT OPERATION 11 6 1 Front panel interface 11 6 1 1 Power on reset 11 6 1 2 Power 11 6 1 3 Backgr...

Page 5: ...g 22 8 7 1 Data monitoring 22 8 7 2 Missing unit monitoring 22 8 7 3 Audio monitoring 22 8 7 4 Unit monitoring 22 8 8 Global Sense test 22 8 9 Access panel timeout 22 8 10 IO Audio timeout 22 9 CUSTOM...

Page 6: ...N 1 TAP PCB CAT6A CONNECTIONS 19 FIGURE 18 N 1 TAP PCB CONTROL CONNECTIONS 20 FIGURE 19 2MX FAULT TREE 24 LIST OF TABLES TABLE 1 FAULT OUTPUT STATES 9 TABLE 2 DEFAULT CONFIGURATION INPUT STATE 9 TABLE...

Page 7: ...nfigurable to allow customisation and modification to the whole Sonix PA GA system Central to the architecture of the Sonix PA GA system is a fully redundant self healing data loop connected via RJ45...

Page 8: ...5 Beacon Bus Beacon bus connections 6 Sync Bus Sync bus connections 7 Power Bus Power bus connections 8 48V Input DC Input connector 9 Fault Output Fault relay output 10 Default Config Communications...

Page 9: ...T6A The 8off pairs of both 8p8c RJ45 style sockets on the rear of the 2Mx are used to connect and communicate with the other units of a Sonix PA GA system Name Color Connected units Data Audio Amp Gre...

Page 10: ...5 Split loop bus data flow The only exception to this is the global bus which is not capable of being a loop 5 4 3 Audio Audio is routed in a similar arrangement to the data control flow There are 2...

Page 11: ...Sonix Hmi 26 see section 8 1 for more details 6 1 4 Local source inputs The local source inputs are comprised of Aux I P and PABX groups Each group has two indicators labelled 1 and 2 The indicators a...

Page 12: ...ible states Pattern State Both off Error not a valid state Solid Green Healthy no issues Fast Flashing Green Duplicate unit ID seen not affecting system operation but should be corrected as soon as pr...

Page 13: ...s not available for normal operation without accepting the ping set request first 6 1 13 Internal Fault Buzzer The 2Mx is provided with an internal buzzer that activates each time a new fault occurs T...

Page 14: ...mplifiers Vw2 Beacon Controller Vw2 Beacon Controller Pbx Fire Gas Ms12 Io Io PABX 2Mx Central Controller 2Mx Central Controller 350 d Ampli er 350 d Ampli er 350 d Ampli er 350 d Ampli er 350 d Ampli...

Page 15: ...Ampli er 350 d Ampli er 350 d Ampli er 350 d Ampli er 350 d Ampli er Vw2 Beacon Controller Vw2 Beacon Controller Controller Vw2 Beacon Controller 2Mx Central Controller 2Mx Central Controller 350 d A...

Page 16: ...Controller Vw2 Beacon Controller Ms12 A Side Access Panel Access Panel Access Panel Access Panel Access Panel Fire Gas Ms12 Pbx Vw2 Beacon Vw2 Beacon Vw2 Beacon Vw2 Beacon Controller Controller Contr...

Page 17: ...er 350 d Ampli er 350 d Ampli er 350 d Ampli er 350 d Ampli er 350 d Ampli er 350 d Ampli er 350 d Ampli er 350 d Ampli er 350 d Ampli er Vw2 Beacon Controller Vw2 Beacon Controller Controller Vw2 Be...

Page 18: ...ler Controller Vw2 Beacon Controller Pbx Access Panel Access Panel Access Panel Access Panel Access Panel Fire Gas Pbx Ms12 Vw2 Beacon Vw2 Beacon Vw2 Beacon Vw2 Beacon Controller Controller Controller...

Page 19: ...ap PCB is required for Amplifier Bus and a second for Beacon Bus if in use The connections for the beacon bus follow an identical pattern to amplifier bus connections shown Unit N Unit 1 Unit 2 Amp Bu...

Page 20: ...ts of the resolved priority and general operation fault diagnostics The recommended maximum cable run for the sync bus is 100m please discuss with your local Eaton representative on longer distances 7...

Page 21: ...Software See SAS manual for details 8 2 3 Amplifier faults In a typical PA GA system amplifiers are the most numerous items To aid with issue tracking the extended 2Mx Sync status report into SAS incl...

Page 22: ...o returning A warning will be raised if a bus stops being a complete loop for audio see 6 1 8 Local Status indicators ote N Hmi Bus connected units access panels are partly wired in spurs they also mo...

Page 23: ...Alarm Tone that is mixed into the Emergency Speech broadcast is set to approximately 12dB lower than the normal Attenuated Alarm This value can be customised to one of the following 1 1 2 5 4 6 8 5 1...

Page 24: ...se Fault Split Loop Solid RED Key Flashing RED Flashing GREEN Ms12 Fault Io Audio Input Fault Amplifier Fault Missing Unit Missing Unit Duplicate Unit ID Duplicate Unit ID Duplicate Unit ID Data Routi...

Page 25: ...red indicator is informing the user that there was an issue on the associated bus but it has been resolved To diagnose the issue users will need to study the log included with SAS assuming that the s...

Page 26: ...aton and SONIX are registered trademarks All other trademarks are property of their respective owners Changes to the products to the information contained in this document and to prices are reserved s...