6 Technical Data
6.1 General rating data
DC1…20… and DC1…OE1 Variable Frequency Drives
02/20 MN040059EN
www.eaton.com
147
Motor feeder
Output voltage
DC1-1D…
U
2
V
3~ 0 - 2 x U
e
(voltage doubler)
DC1-12…, DC1-32…, DC1-34…
U
2
V
3~ 0 - U
e
Maximum length of motor cable
l
m
100 (shielded)
200 (unshielded)
Assigned motor output
at 230 V, 50 Hz
P
kW
0.37 - 4
at 400 V, 50 Hz
P
kW
0.75 - 22
Output Frequency
Range, parameterizable
f
2
Hz
0 - 50/60 (max. 500 Hz)
resolution
Hz
0.1
Rated operation current
I
e
A
2.3 - 46
Overload current for 60 s every 600 s
i
l
%
150
Overload current for 2.5 s every 600 s
i
l
%
175
Switching frequency (double modulation)
f
PWM
kHz
max. 32
Operating mode
V/Hz control (speed accuracy)
±20 %, with slip compensation
Vector control
(static speed accuracy)
±0.033 %
±1% load range: 0 - 100 %
Torque response time
t
r
ms
1 - 8
Torque linearity
±5 % (10 - 90 % of speed variable range,
20 - 100% of torque load range)
Response time (enable IGBT)
t
r
ms
< 10
DC braking
Time before start
t
s
0 - 25, in the event of a stop
Motor pick-up control function (for catching spinning
motors)
all frame sizes
Brake chopper
only for sizes FS2 to FS4
Braking current during continuous operation
%
100 (I
e
)
Maximum braking current
%
150 for 60 s
Technical data
Symbol
Unit
Value
Summary of Contents for PowerXL DC1-122D3NN-A20CE1