i-on160EX
Technical Specification
Page 35
*Note: The ratings given here represent the
maximum current that can be drawn before
triggering over-current protection.
EN50131-6 ratings
The i-on160EX provides space for two 17Ah
batteries, giving a total of 34Ah charge.
Under EN50131-1 for Security Grade 3
installations the required battery standby time is
30 hours, provided the system is fitted with an
ATS4 communicator capable of transmitting a
mains fail signal
This means that all the devices powered by those
backup batteries, including the control unit and at
least one keypad, should together draw no more
in total than an average of 1.1A over a 30 hour
standby time. Note that for Security Grade 3 the i-
on160EX must use a plug-by
(“stand alone”)
communicator, which may have its own power
supply.
Under PD6662, battery standby time requirements
for Security Grade 3 drop to 12 hours, provided
the system is fitted with an ATS4 communicator
capable of transmitting a mains fail signal.
For Security Grade 2 the required battery standby
time is 12 hours. However, the total average
current available over 12 hours from the batteries
is limited by the power supply to 1.5A. (The
current is limited to 1.5A because when mains is
present the 3.0A power supply reserves 2x750mA
to recharge batteries, leaving 1.5A available to
supply the system.)
To meet Security Grade 2 the control unit can be
fitted with a plug-on communicator, for example
the i-sd02.
The table below shows the current consumption of
the control unit and each device that can be fitted
to it.
CIE power
requirement:
140mA min.
220mA max
i-kp01 power
requirement:
30mA (normal/idle)
45mA (backlight low)
65mA (backlight high)
KEY-
KPZ01/KP01/K01
power requirement
35mA backlight OFF,
internal prox reader only.
65mA max backlight ON,
external prox reader
connected
Wired Expander
requirement
20mA max quiescent.
300mA in alarm if
sounder connected.
Radio Expander
requirement
40mA max quiescent
320mA in alarm if
sounder connected.
Battery charging
requirement:
750mA per battery
(recharge within 24 hrs)
Plug-on
Communicator power
requirement:
i-sd02, i-dig02:
20mA quiescent
50mA max
Plug-on
Communicator power
requirement
i-gsm02:
150mA quiescent
and max.
Plug-by
Communicator pins
require:
5mA each when active.
10 FSL zones
20mA
5x4-wire CCL zones
30mA
12V Bus output
voltage range :
10±0.5V to 13.8V
12V Aux output
voltage range:
10±0.5V to 13.8V
12V Bell output
voltage range
10±0.5V to 13.8V
14.4V output voltage
range:
10±0.5V to 14.7V
Max p-to-p ripple
voltage:
0.5V
Standby Battery:
12V, 17Ah sealed lead
acid, 2 off (not supplied).
‘Low battery’ fault at:
< 12V
Aux power output fault
at:
< 9V
Deep discharge
protection at:
10±0.5V
Overvoltage protection
trigger voltage
15.6±1.0V
Serviceable
components:
Mains fuse: 500mA (T)
Standby time:
See “Power Availability”
on page 11.
Electromagnetic
Compatibility
Immunity
Conforms to EN50130-4.
Emissions
Conforms to EN61000-6-3.
Outputs
Panel:
O/P 1 - 2
Voltage free, single pole relay
contacts rated 24VDC @ 1A.
Panel:
O/P 3 - 4
Open collector transistor,
+12VDC when inactive, 0V
when active. 500mA max.
Plug-by O/P 1-
16
Open collector transistor
+12VDC when inactive, 0V
when active, 50mA max.
LS 1 & 2
(loudspeaker)
Min impedance 16 Ohm per
output, current consumption =
280mA in alarm.
Expander:
Outputs
Open collector transistor,
+12VDC when inactive, 0V
when active. 500mA max.
Note: The current is limited by
the amount available from the
power supply driving the
expander.
KEY-KPZ01
Outputs
Open collector transistor,
+12VDC when inactive, 0V
when active, 500mA max.