Installer Menu 

1 DETECTORS/ DEVICES 

Detectors  

Add/Del Detectors

1

  

Program Zones 

Address Bus Device 
Wired Expanders 

Address Bus Device 
Edit Expander 
Delete Expander 
Enable Expander 
Replace Expander 

Radio Expanders 

Address Bus Device 
Edit Expander 
Delete Expander 
Enable Expander 
Replace Expander 

Wired Keypads 

Address Bus Device 
Edit Keypad 

Keypad 01...45 

Name 
Partitions

2

  

Key A...D

2

  

Zones

23

 

Wired zone type

23

 

Backlight

24

 

External Prox

25

 

Delete Keypad 
Enable Keypad 
Replace Keypad 

Radio Keypads  

Add/Del Radio Keypad  
Edit Keypads  

Radio Keypad 01...20

1

 

Name 
Partitions

2

  

Key A...D

2

  

External Sirens  

Add/Del Siren 
Edit Siren 

WAMs 

Add/Del WAM 
Edit WAM 

2 OUTPUTS 

Radio outputs

1

 

Add Outputs  
Edit Outputs  

Wired outputs  

Panel  
 

Siren 

 

Strobe 

 

PAN>OP1

…OP4 

Exp. x1-nn... 
 

O/P x1>nn>1...4 

 

   Name 

 

   Type 

 

   Polarity 

 

   Pulsed 

 

   Partitions

2

 

Plug-by outputs 

Output 01...16 

Name 
Type 
Polarity 
Pulsed 
Partitions

2

 

3 SETTING OPTIONS

3

  

Full Set 

Name 
Exit mode  
Settle time

4

 

Exit time

5

 

Entry time 
Siren delay 
Siren time 
Strobe on Set 
Strobe on Unset 

Part Set B 

Name  
Exit Mode  
Settle time

4

 

Exit time

5

 

Entry time 
Alarm Response  
Siren delay 
Siren time 
Part Set Final Exit 
Part Set Entry Route 
Strobe on Set 
Strobe on Unset 

Part C, D  
(See Part Set B) 
Calendar Set 

3 PARTITIONS

2

  

Partition 1 

Name 
Exit mode 
Settle time

4

 

Exit time

5

 

Entry time  
Alarm response 
HUA response 
Siren delay 
Siren time 
Strobe on Set 
Strobe on Unset 
Part set exit mode  
Part set settle time

4

 

Part set exit time

5

 

Part set entry time 
Part set alarm resp. 
Part set siren delay 
Part set siren time 
Part set final exit 
Part set entry route 
Part set strobe set 
Part set strobe unset 

Partition 2....20 
Full Set Link 

Partition 2...20 

Calendar Set 

Add Event 
Edit Event 
Delete Event 
Add Exception 
Edit Exception 
Delete Exception 

4 SYSTEM OPTIONS 

Wired Zone type 

Panel Zones 
All Zones 

User Access 

HUA keys active  

Quick set 
Quick omit 
User code reqd 
2 Way Replies 
2w Set Instant 
Duress Enable 

User reset 

Zone alarms

6

 

Zone tampers 
System tampers 

Confirmation (UK version) 

Confirmation Mode  

Basic 
DD243 
BS8243 

Confirmation time

7

 

After entry

7

 

Entry keypad lock

7

 

Sounder on 
Siren on 
Unconfirmed reset

7

 

Confirmed reset

7

 

HUA Confirm Time

Tamper as Tamper only 

Confirmation (-EUR 
version) 

Sounder on 
Siren on 

Masking 
Mask Override

9

 

Language

10

 

Restore defaults 

Staged defaults 
Factory defaults 

Installer name 
Installer code  
Keypad text 
Remote needs Entry 
Remote Entry PrtSt 
RKP Needs Entry 
RKP Entry PrtSt 
HUA Response

11

 

Auto Rearm

6

 

Panel Loudspeaker 
Entry alarm delay 
Abort Time 
Supervision 
Jamming 
Force Set 
Tamper Omit 
CSID Code 
Silence Alerts 
Mains Fail Delay 
Battery 2 
Set Date & Time 
Panel Tamper Rtn 

5 COMMUNICATIONS 

ARC Reporting

13

  

Call Mode 
Phone book 
IP Network

13

 

Account Numbers 
Report Type 
Fast Format channels

14

 

CID/SIA Events

15

 

Restorals  
Burg Comms Rearm

19

 

21CN FF Ack time

14

 

Send tamper as burg

15

 

Dynamic Test Call

16

 

Static Test Call

17

 

Unset Comms 

Speech Dialler

13

 

Call Mode 
Messages 
Phone Book 
Triggers 
Destinations 
Call Acknowledge 

SMS

13

 

Call Mode 
Messages 
Phone Book 
Triggers 
PSTN SMS

13

 

Line Fail Response

12

 

Line Fail Delay

12

 

IP Network (Own) 

Web Server 
 

Status 

 

Port Number 

 

VKP Instant 

Downloader 
IP Address 
Subnet Mask 
Gateway Address 

GPRS

13

 

Ethernet

13

 

Downloading 

Account 
Connection Type 
Rings to Answer

13

 

Answer on 1 ring

13

 

Access Mode 
Phone Book

13

 

IP Network

22

 

Secure Callback

13

 

Modem Baud Rate

13 

Remote Servicing

21 

Plug-by 

6 TEST  

Sirens & Sounders 
Wired Keypad 
Radio Keypads 
Expanders 
Walk Test 
Zone Resistances 
Signal Strengths 

Detectors 
Radio Keypads 
External Sirens  
WAMs 

Outputs  

Radio Outputs 
Wired Outputs 
Plug-by Outputs 
Expander Outputs 

Remotes  
User HUAs  
Prox Tags  
ARC Reporting

13

 

Speech Dialler

13

 

PSU Current

18

 

Battery(s) 
Locate Bus Device 
(cont’d next page) 

Summary of Contents for i-on160EX

Page 1: ...i on160EX Security System Installation Guide Issue 9...

Page 2: ...quipment but will not damage the equipment Caution Describes actions that will physically damage the equipment and prevent its proper function WARNING Describes actions that are hazardous to health or...

Page 3: ...Cabling 19 Step 6 Connect Wired Zones 20 Four Wire Closed Circuit Connections 20 Two Wire Closed Circuit Connections 20 Fully Supervised Loop Connections 20 Shock Sensors and Roller Shutter Sensors 22...

Page 4: ...i on160EX Page iv This page is intentionally blank...

Page 5: ...sed as part of a Security Grade 3 system The control unit is also approved to operate as part of a Security Grade 2 system If you install any radio devices this will limit approval to Security Grade 2...

Page 6: ...or laptop connected to the Ethernet port on the control unit PCB The control unit contains a web page server and you can use any web browser to see a complete version of the Installer menu Please see...

Page 7: ...tion can all affect the signal from a transmitter Please read Eaton s Security Business publication Guidance Notes for Wireless Alarm System Installations obtainable from www coopersecurity co uk for...

Page 8: ...tal or conducting films These glasses are particularly poor at transmitting radio waves Guided Tour CAUTION All printed circuit boards for the i on160EX its expanders and keypads have been tested for...

Page 9: ...tors 11 RS485 terminator 12 Engineering keypad connector 13 Zone output Aux power and Bus connectors 14 Kickstart pins Batt 1 only 15 Battery connectors two of 16 20Vac connector 17 USB socket Mini B...

Page 10: ...ixed To open the keypad first gently prise off the trim on the front and remove the two screws Next carefully lever the front of the keypad containing the PCB and display away from the keypad rear hou...

Page 11: ...e bottom edge of the caps in with the end of a small screwdriver to start them Remove the two screws hidden underneath see Figure 9 Gently swing the lower side of the front out from the back box by ab...

Page 12: ...amper switch 2 Sounder 3 Connector for KEY EP Terminals for zones 4 Sounder volume control 5 Connector for control unit bus and output terminal 6 Jumpers for 6a Addressing not used in i onEX control u...

Page 13: ...er connectors 19 Outputs Figure 15 EXP W10 Wired Expander 1 Cable entry also behind PCB 2 Central keyhole 3 PCB 4 Relay card i rc01 connector 5 Aux power 6 Link to enable disable front rear tamper swi...

Page 14: ...able front rear tamper switch 6 Lid tamper rear tamper behind PCB 7 Bus termination jumper 8 Addressing button 9 Fixing holes 10 Engineering keypad connector 11 Bus cable connector 12 Sounder 13 Louds...

Page 15: ...and would meet the EN50131 1 Grade 3 requirements A single new fully charged charged 17A battery can provide the charge required by the example system for PD6662 Grade 3 requirements Note All current...

Page 16: ...only two arms on the star then this is the same as a daisy chain configuration see Daisy Chain 1 in Figure 18 If required fit the termination jumper at the devices on the end of each arm If there are...

Page 17: ...4 03V 4 61V 5 18V 5 76V 380mA 0 61V 1 22V 1 82V 2 43V 3 04V 3 65V 4 26V 4 86V 5 47V 6 08V 400mA 0 64V 1 28V 1 92V 2 56V 3 20V 3 84V 4 48V 5 12V 5 76V 6 40V Reducing Voltage Drop Method 1 Double up th...

Page 18: ...k the position of the case Also mark the position where the lid back tamper bracket touches the wall There must be enough space around this point to fit the supplied tamper shroud see Figure 21 Fittin...

Page 19: ...s the KEY EP or prox readers used by other systems for example access control systems If you mount prox readers closer together than one meter including on the other side of walls then the two prox re...

Page 20: ...lights by fitting links over the BRIGHT jumper on the keypad pcb see 1b in Figure 12 or 6b in Figure 14 Jumper OFF The keypad backlights glow at normal intensity Jumper ON The keypad backlights glow e...

Page 21: ...al programming mode and save your changes see below To Disable Enable the Status OK LED 1 Enter Local Programming mode MENU ABCD 2 Press repeatedly until the display shows MENU STATUS OK LED 3 Press r...

Page 22: ...ou do so then the prox readers will interfere and be unable to read tags Opening the External Prox Reader To open the external prox reader see Figure 27 1 Undo the single retaining screw 2 Tilt the ed...

Page 23: ...Expanders Addressing Expanders The control unit assigns addresses to all devices connected to the bus cable You can start this process off from the Installer Menu during the initial power up See Initi...

Page 24: ...wiring for CCL zones on the KEY KPZ01 Figure 35 KEY KPZ01 CCL Zone Wiring Two Wire Closed Circuit Connections With version 4 02 and higher software you can connect two wire CCL detectors to each pair...

Page 25: ...xamples Figure 39 Wiring FSL Zones on KEY KPZ01 When programming select the FSL resistor values for the control unit in Installer Menu System Options Wired Zone Type To select the resistor values for...

Page 26: ...istors and are capable of sinking a maximum 500mA when active By default outputs 3 and 4 are 0V when active 12V when inactive If you wish to reverse the polarity of these two outputs see Changing the...

Page 27: ...the alarm contacts only and link the tamper contacts together with a short length of wire In the Installer Menu program the zone with a type of Tamper Program the outputs used to trigger the siren and...

Page 28: ...pes See the i on Range Engineering Guide for details on how to change the defaults Figure 48 Plug By Communicator Wiring Note Comms O P4 will be active when the system is unset This is normal To fit a...

Page 29: ...connector The control unit will generate an ATE L F Single alert if only one of the networks is not available or ATE L F All if both networks are not available Step 9 Fit and Connect Battery Fit eithe...

Page 30: ...you have connected a battery to the BATT2 terminals and wish to enable fault reporting on battery 2 The display shows 8 Press or to show the Security Grades available for example 9 Press to select the...

Page 31: ...briefly display the message Installer session transferred for 5 seconds before reverting to the time and date Leaving the Installer Menu If you wish to leave the Installer Menu at any time 1 Press un...

Page 32: ...ion complies with BS8243 only if the user has given written consent 3 If you key in an access code incorrectly the display shows four stars Key in the code again If you key in a total of four incorrec...

Page 33: ...to select the desired mode The display shows 6 Press or to display the desired Security Grade 2 or 3 on the bottom line of the display and then press to select it The display shows 7 Press or to displ...

Page 34: ...make sure that you allocate keypads correctly to partitions For more information see Assigning Wired Keypads to Partitions in the i on Range Engineering Guide Assemble and close the control unit a Fit...

Page 35: ...OPTIONS Wired Zone type Panel Zones All Zones User Access HUA keys active Quick set Quick omit User code reqd 2 Way Replies 2w Set Instant Duress Enable User reset Zone alarms 6 Zone tampers System t...

Page 36: ...17 Appears only when Dynamic Test call disabled 18 Appears only if EXP PSU is fitted 19 Appears only when Report Type Fast Format AND Confirmation Mode Basic 20 Shows None if no module fitted 21 Must...

Page 37: ...if you wish to find the location of any keypad or expander you can employ the Test Locate Bus Device option in the Installer Menu Use this option to make a selected bus device give a continuous tone...

Page 38: ...ts 1 500 mandatory events 500 non mandatory Stored in EEPROM memory available for at least 10 years without power Internal Clock 10 minutes over one year depending on the accuracy of the mains supply...

Page 39: ...65mA backlight high KEY KPZ01 KP01 K01 power requirement 35mA backlight OFF internal prox reader only 65mA max backlight ON external prox reader connected Wired Expander requirement 20mA max quiescent...

Page 40: ...Grade 2 The i sd02 is compliant with EN50136 1 as an ATS2 communicator The i sd02 may be used as a supplementary communicator at Grade 3 At Grade 2 the i sd02 provides a compliant communicator for th...

Page 41: ...i fb01 Four button remote control 727rEUR 00 Four button remote control with encrypted code HUD function not compatible with BS8243 or DD243 Communicators i dig02 PSTN Communication ARC only i gsm02 G...

Page 42: ...i on160EX Page 38 This page is intentionally blank...

Page 43: ...i on160EX Page 39 This page is intentionally blank...

Page 44: ...www coopersecurity co uk Product Support UK Tel 44 0 1594 541978 Available between 08 30 to 17 00 Monday to Friday Product Support Fax 01594 545401 email techsupport coopersecurity co uk Part Number...

Reviews: