5. Technical Specification
General
Product name
i-on160EX.
Product
Description
160 zone endstation with
remote keypads.
Manufacturer
Eaton’s Security Business.
Environmental
Class II.
Operating
temperature
Tested -10 to +55°C.
Humidity
0 to 93% RH, non-condensing.
Case material
Steel.
Dimensions:
Control unit
427 x 400 x 101, mm HxWxD.
i-KP01
115 x 156 x 30, mm HxWxD
KEY-
K01/KP01/KPZ01
128 x 128 x 29, mm HxWxD
EXP-W10, EXP-
WCC, EXP-R10,
EXP-R30
230 x 144 x 44, mm HxWxD
Weight:
Control unit
6 kg (without stand-by
batteries).
i-KP01
0.26 kg
KEY-K01
0.19 kg
KEY-KP01
0.19 kg
KEY-KPZ01
0.19 kg
EXP-W10,
EXP-WCC,
EXP-R10, EXP-
R30
0.42 kg
0.43 Kg
0.39 kg
0.39 kg
Capacities
Zones
160 max (with expanders)
Outputs
16 plug-by communicator
outputs on control unit, plus
160 max for the rest of the
system, comprising:
4 wired on control unit (two
transistor and two relay)
4 transistor based on each wired
expander
8 radio outputs on each 768/769
2 radio outputs on each 762
Expanders and
Wired Keypads
45 max devices (see note 1)
Radio Keypads
20 max (two per radio expander)
External Radio
Sirens
20 max (two per radio expander)
WAMs
20 max (two per radio expander,
repeater mode only)
Loudspeakers
2 on control unit, one per
expander
Plug on
communication
modules
One
Other ports
1 x USB, 1 x Ethernet
Partitions
20 (see note 2)
Calendar Set
Timers
20 max
Log capacity
Up to 2,000 events: 1,500
mandatory events, 500 non-
mandatory. Stored in EEPROM
memory, available for at least 10
years without power.
Internal Clock
±10 minutes over one year
(depending on the accuracy of
the mains supply frequency).
User Codes
500 (plus installer code)
Remote controls
500 (one per user)
Panic Alarms
500 (one per user)
Proximity tags
500 (one per user)
Notes:
1. Wired keypads, wired zone expanders, and
radio zone expanders are all bus devices. You
can connect any combination of these devices
to the bus.
2. The system can be used as EITHER a partitioned
system OR a part setting system. When used as a
part setting system there are four setting levels
available: Full Set and Part Sets B, C and D.
Security
Security Grade
Grade 2 or 3
Radio detector
differs
16,777,214 (2
24
-2).
Radio
Supervision
Programmable.
Number of
access codes
500 plus one installer
Access code
differs
10,000 differs with 4 digit
codes.
1,000,000 differs with six digit
codes.
All digits may be any number 0
to 9.
Code blocking
Blocked for 90s after four
incorrect codes in series.
Proximity tag
differs
4,294,967,296 (2
32
)
Power Supply
This product complies with the requirements of EN50131-6
Type A power supply at Grade 3 and environmental class 2.
Power supply type
A
Mains power supply
requirements
10%/-15%,
350mA max, 50Hz.
Total power supply
capacity:
3.0A (of which 1.5A is used
for battery recharge and
1.5A is available for
powering the system).
12V Aux supply*:
850mA max
12V Bell supply
850mA max
14.4V output*:
230mA max
Comms power
supply*:
400mA max
12V Expander Bus*:
400mA max
LS connectors
280mA in alarm.