background image

Page 

4

Key features

This section provides an overview of the 
key features, from a user’s perspective, of 
i-on Style alarm systems.

Comprehensive set/unset flexibility

There are many options available to 
the installer to configure the setting/
unsetting process to match your specific 
requirements.

If at any time, your requirements change, 
please contact your installer, who may 
be able to adjust the set/unset procedure 
without making any physical changes.

Social care and medical alerting

i-on Style systems are 
compatible for use in social-care 
applications, where there is need 
to provide constant care for 
elderly or infirm people.

An installer can, for example, set up the 
system to monitor an area, and generate 
an alert if no activity is detected during 
periods of the day.

The system can be set up to respond to an 
alert in many different ways. For example, 
by sending an email or text message, 
switching on a dedicated sounder, or 
sending a pre-recorded speech message to 
a nominated telephone number.

The control unit’s built-in microphone 
and loudspeaker enable the recipient of a 
speech message to communicate two-way 
with the person seeking assistance.

If required, each person can also have a 
unique medical and/or social-care pendant. 
Pressing the button on the pendant 
activates a medical alarm or social-care 
alert. If a pendant is not available, the 
same action can be carried out by pressing 
the Hot key at the control unit.

Alarm communication

When the system detects an alarm, it starts 
the external sounder/strobe units and 
operates internal sounders, including the 
sounder in the control unit.

If you wish, your installer can also 
configure the control unit to communicate 
alarms externally to:

 

• An Alarm Receiving Centre (ARC), via 

the internet, a fixed-line telephone 
network or a mobile network. 

 

• An email address.

 

• A mobile phone using a text message.

 

• A specified telephone number using a 

pre-recorded speech message.

Note: Communications via a fixed-line 
phone network or the internet is provided 
as standard. Communications across a 
mobile network requires the installer to fit 
a GSM module.

Voice memo recording/playback

You can use the voice memo 

feature to record a message. Any 
user can replay the memo when 
unsetting the system, or at any 

other time through the User menu.

Proximity tags

Each user can have a unique 
proximity tag. When presented to 
the control unit, the tag performs 
the same action as entering your 
access code.

Proximity tags make it easier for you to set 
or unset the system, and there is no need 
to remember an access code.

Home key

The control unit has a “Home” 

key, which the installer can 

configure to set or part set the system, or 
switch an external device (output) on or 
off, without you needing to use an access 
code or proximity tag.

Summary of Contents for i-on Style

Page 1: ...o keypads 3 Internal radio sounders 3 Output devices 3 Key features 4 Comprehensive set unset flexibility 4 Social care and medical alerting 4 Alarm communication 4 Voice memo recording playback 4 Pro...

Page 2: ...over a phone link Keypad This allows you to set or unset the system access user options and acknowledge alarms You can identify yourself to the system by entering your unique access code at the keypa...

Page 3: ...arms PAs allow you to start alarms remotely Network cameras Internal and external network cameras are available These allow the control unit to record and optionally email images when an alarm occurs...

Page 4: ...ates a medical alarm or social care alert If a pendant is not available the same action can be carried out by pressing the Hot key at the control unit Alarm communication When the system detects an al...

Page 5: ...be useful if you have an area that needs to be left unset at certain times such as the upstairs during the night The system also allows the installer to define common areas such as hallways which set...

Page 6: ...ay speech communication If configured the control unit can send a pre recorded speech message to one or more telephone numbers when a specified alarm or alert occurs Once received the recipient can in...

Page 7: ...n or acknowledgement of an alarm Carries out a full system set Carries out a full system unset Hot key The installer can configure this key to generate a Medical alarm or Social Care alert A Hold Up A...

Page 8: ...s the partitions that you have access to and their current state Partition 1 U Partition 2 U U unset P part set S set Press or to highlight the partition then or to select the change you want Partitio...

Page 9: ...ows the alarm s For example P1 Burg Z001 Alarm P3 Burg Z002 alarm Reset OR Call Installer P1 Panel lid open P2 Panel lid open P3 Panel lid open P4 Panel lid open P1 P2 P3 and P4 are the partition numb...

Page 10: ...on The display lists the zones you can omit Study I Garage An O is displayed at the end of the line if the zone is Omitted An I is displayed if the zone is Included 3 Press or to display the zone you...

Page 11: ...Page 11 NOTES...