background image

i-on Style Security System

User Guide

LCD display

Keypad

Proximity 
tag reader

Loudspeaker

 

Microphone 
(internal)

Figure 1.  i-on Style control unit

About this guide

This guide provides an 
introduction to i-on Style alarm 
systems for users. It describes the 
main components of the alarm 
system, the key features and how 
to carry out typical day-to-day 
tasks.

If you need additional 
information, including details of 
the options in the User menu, 
please refer to the i-on Style 
Administration and User Manual.

Contents

About this guide   .  .  .  .  .  .  .  .  .  .  .  .  .  . i
About i-on Style    .  .  .  .  .  .  .  .  .  .  .  .  . 2
System components   .  .  .  .  .  .  .  .  .  . 2

Control unit . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Detectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
External sirens  . . . . . . . . . . . . . . . . . . . . . . . 3
Remote controls  . . . . . . . . . . . . . . . . . . . . . . 3
HUA transmitters  . . . . . . . . . . . . . . . . . . . . . 3
Network cameras  . . . . . . . . . . . . . . . . . . . . . 3
One-way radio keypads . . . . . . . . . . . . . . . . 3
Internal radio sounders  . . . . . . . . . . . . . . . . 3
Output devices  . . . . . . . . . . . . . . . . . . . . . . . 3

Key features   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 4

Comprehensive set/unset flexibility  . . . . . . 4
Social care and medical alerting. . . . . . . . .  4
Alarm communication  . . . . . . . . . . . . . . . . . 4
Voice memo recording/playback . . . . . . . . . 4
Proximity tags . . . . . . . . . . . . . . . . . . . . . . . . 4
Home key   . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Hot key   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Partitioned and part-setting modes   . . . . . . 5
Calendar setting/unsetting   . . . . . . . . . . . . . 5
System control using SMS texts   . . . . . . . . 5
Multiple users and user types. . . . . . . . . . .  5
Wide range of peripherals . . . . . . . . . . . . . . 5
Camera integration   . . . . . . . . . . . . . . . . . . . 5
Control of external devices (outputs) . . . . . 6
HUA/panic/duress alarms  . . . . . . . . . . . . . . 6
Installer remote access  . . . . . . . . . . . . . . . . 6
Two-way speech communication  . . . . . . . . 6
Wide range of user options . . . . . . . . . . . . . 6
Ability to omit zones  . . . . . . . . . . . . . . . . . . 6
Full logging . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Jamming and tamper monitoring   . . . . . . . 6
Comprehensive test options  . . . . . . . . . . . . 6

Using i-on Style  .  .  .  .  .  .  .  .  .  .  .  .  .  . 7

Control unit keypad  . . . . . . . . . . . . . . . . . . . 7
About the standby screen  . . . . . . . . . . . . . . 7
Setting the system  . . . . . . . . . . . . . . . . . . . . 8
Unsetting the system . . . . . . . . . . . . . . . . . . 8
Managing alarms  . . . . . . . . . . . . . . . . . . . . . 9
Accessing the User menu  . . . . . . . . . . . . . . 9
Omitting zones  . . . . . . . . . . . . . . . . . . . . . . 10
Recording and playing a voice memo  . . . 10

Summary of Contents for i-on Style

Page 1: ...o keypads 3 Internal radio sounders 3 Output devices 3 Key features 4 Comprehensive set unset flexibility 4 Social care and medical alerting 4 Alarm communication 4 Voice memo recording playback 4 Pro...

Page 2: ...over a phone link Keypad This allows you to set or unset the system access user options and acknowledge alarms You can identify yourself to the system by entering your unique access code at the keypa...

Page 3: ...arms PAs allow you to start alarms remotely Network cameras Internal and external network cameras are available These allow the control unit to record and optionally email images when an alarm occurs...

Page 4: ...ates a medical alarm or social care alert If a pendant is not available the same action can be carried out by pressing the Hot key at the control unit Alarm communication When the system detects an al...

Page 5: ...be useful if you have an area that needs to be left unset at certain times such as the upstairs during the night The system also allows the installer to define common areas such as hallways which set...

Page 6: ...ay speech communication If configured the control unit can send a pre recorded speech message to one or more telephone numbers when a specified alarm or alert occurs Once received the recipient can in...

Page 7: ...n or acknowledgement of an alarm Carries out a full system set Carries out a full system unset Hot key The installer can configure this key to generate a Medical alarm or Social Care alert A Hold Up A...

Page 8: ...s the partitions that you have access to and their current state Partition 1 U Partition 2 U U unset P part set S set Press or to highlight the partition then or to select the change you want Partitio...

Page 9: ...ows the alarm s For example P1 Burg Z001 Alarm P3 Burg Z002 alarm Reset OR Call Installer P1 Panel lid open P2 Panel lid open P3 Panel lid open P4 Panel lid open P1 P2 P3 and P4 are the partition numb...

Page 10: ...on The display lists the zones you can omit Study I Garage An O is displayed at the end of the line if the zone is Omitted An I is displayed if the zone is Included 3 Press or to display the zone you...

Page 11: ...Page 11 NOTES...

Page 12: ...S DOCUMENT SHALL NOT BECOME PART OF OR MODIFY ANY CONTRACT BETWEENTHE PARTIES In no event will Eaton be responsible to the purchaser or user in contract in tort including negligence strict liability o...

Reviews: