background image

Page 

8

Setting the system

Readying the system to start an alarm if 
someone moves into a protected area is 
called “setting” the system. 

You can set your system using a variety of 
different methods, depending on system 
configuration. The following explains a 
typical method using the control unit.

Note: Please refer to the Administration 
and User Manual for full details.

1.  Enter your access code or present your 

proximity tag at the control unit. If you 
enter your access code, the display 
shows a 

V

 for each completed digit:

          

Enter Access Code

              

V  v  v  v

2.  Setting options are displayed. For 

example:

Full Set All

Part Set All

Partitions    

                     

3.  Press 

 or 

 followed by 

 to choose 

the option you require:

 

Full Set (part-setting system only): To 
set the whole system.

 

Part Set B\C\D (part-setting system 
only): To set part set B, C or D only.

 

Full Set All (partitioned system 
only): To set all partitions fully. This 
is available only if all partitions are 
currently unset.

 

Part Set All (partitioned system only): 
To part set all partitions.

 

Partitions (partitioned system only): 
To choose the partition(s) to set, and 
whether to full set or part set those 
partitions. The display shows the 
partitions that you have access to, 
and their current state:

Partition 1                        U

Partition 2                        U

“U” = unset 
“P” = part set 
“S” = set

Press 

 or 

 to highlight the 

partition, then 

 or 

 to select the 

change you want:

Partition 1                     U>S

Partition 2                     U

“U>S” = change unset to full set 
“U>P” = change unset to part set 
“S>U” = change full set to unset 
“P>U” = change part set to unset
 If required, choose to change the 
state of other partitions, and press 

 

to continue. 

4.  You will hear a continuous exit tone 

(unless the system is configured for 
silent or instant setting).
 The system sets when one of the 
following occurs, depending on how 
the system is configured:

 

• Immediately.

 

• After a period of time. 

 

• When you have exited the premises 

and either pressed an exit-terminate 
button, closed the final door or 
operated a lock.

Unsetting the system

Disarming the system so that people 
can move freely is called “unsetting” the 
system.

To unset the system from the control unit:

1.  Enter through the designated entry 

route. Do not stray from this route – 
you may cause an alarm.

2.  If you hear a tone, go directly to the 

control unit, since you will have limited 
time to unset the system before it 
generates an alarm.

3.  Enter your access code or present your 

proximity tag.

4.  If you are using a partitioned system:

a.  The display shows the partitions 

that you have access to and their 
current state, as shown next.

Summary of Contents for i-on Style

Page 1: ...o keypads 3 Internal radio sounders 3 Output devices 3 Key features 4 Comprehensive set unset flexibility 4 Social care and medical alerting 4 Alarm communication 4 Voice memo recording playback 4 Pro...

Page 2: ...over a phone link Keypad This allows you to set or unset the system access user options and acknowledge alarms You can identify yourself to the system by entering your unique access code at the keypa...

Page 3: ...arms PAs allow you to start alarms remotely Network cameras Internal and external network cameras are available These allow the control unit to record and optionally email images when an alarm occurs...

Page 4: ...ates a medical alarm or social care alert If a pendant is not available the same action can be carried out by pressing the Hot key at the control unit Alarm communication When the system detects an al...

Page 5: ...be useful if you have an area that needs to be left unset at certain times such as the upstairs during the night The system also allows the installer to define common areas such as hallways which set...

Page 6: ...ay speech communication If configured the control unit can send a pre recorded speech message to one or more telephone numbers when a specified alarm or alert occurs Once received the recipient can in...

Page 7: ...n or acknowledgement of an alarm Carries out a full system set Carries out a full system unset Hot key The installer can configure this key to generate a Medical alarm or Social Care alert A Hold Up A...

Page 8: ...s the partitions that you have access to and their current state Partition 1 U Partition 2 U U unset P part set S set Press or to highlight the partition then or to select the change you want Partitio...

Page 9: ...ows the alarm s For example P1 Burg Z001 Alarm P3 Burg Z002 alarm Reset OR Call Installer P1 Panel lid open P2 Panel lid open P3 Panel lid open P4 Panel lid open P1 P2 P3 and P4 are the partition numb...

Page 10: ...on The display lists the zones you can omit Study I Garage An O is displayed at the end of the line if the zone is Omitted An I is displayed if the zone is Included 3 Press or to display the zone you...

Page 11: ...Page 11 NOTES...

Page 12: ...S DOCUMENT SHALL NOT BECOME PART OF OR MODIFY ANY CONTRACT BETWEENTHE PARTIES In no event will Eaton be responsible to the purchaser or user in contract in tort including negligence strict liability o...

Reviews: