Diesel Engine
Fire Pump Controllers
BR081011EN
April 2015
Reduced Size
A streamlined internal design has
allowed the overall size of the DIESEL
Plus controllers to be reduced from
previous models. See dimensional
drawings on our website.
Technical Specifi cations
• Supply
Voltage:
100-240Vac
• Output
Voltage:
12-24Vdc
•
Hertz: 50/60 Hz
• Enclosure:
Standard NEMA 2
•
Optional NEMA 3R, 4, 4X, 12
• Temperature:
4 to +50 deg. C
39 to +122 deg. F
•
Alarm Relays: DPDT 8amp
•
Engine Run Relay:
DPDT 10amp
•
Crank / Fuel Stop Relays: SPDT
• Pressure
Transducer:
500psi
• Immunity
Compliance:
Environment A
• Emission
Compliance:
Environment B
Battery Chargers
• Mode:
Switching
•
Dual 10 Amp
•
Communication to Power
I/O Board
• Diagnostics
Recording
•
Lead Acid or NiCadThree Step
Charge
• Internal
Temperature
Monitoring
• Universal
Voltage
Input
•
Selectable Dual Voltage Output
Standards & Certifi cation
The FD120 Diesel Engine Fire
Pump Controllers meet or exceed
the requirements of Underwriters
Laboratories, Factory Mutual
Research (FM), the Canadian
Standards Association, New York City
building code, CE mark and U.B.C. /
C.B.C Seismic requirements, and are
built to NFPA 20 standards.
LCD Display
The Controller Display Board contains
a 4 Line by 40 Characters wide, back-
lit, LCD display which is capable of
generating multiple languages. The
display will show the current system
pressure, time and date, charger
output voltage and any custom mes-
sages, alarms or timer values.
Status LED's
The controller is supplied with six (6)
green status LED's for the following:
• LOW
PRESSURE
• ENGINE
RUN
• REMOTE
START
• INTERLOCK
ON
• DELUGE
VALVE
•
One Programmable LED
Alarm LED's
The controller is supplied with
twenty (20) red alarm LED's for the
following:
•
BATTERY #1 FAILURE
•
CHARGER # 1 FAILURE
•
BATTERY #2 FAILURE
•
CHARGER # 2 FAILURE
•
LOW PRESSURE
•
SYSTEM OVER PRESSURE
•
LOW SUCTION PRESSURE
• LOW
FUEL
•
FAIL TO START
• HIGH
ENGINE
TEMP
•
LOW OIL PRESSURE
•
ENGINE OVER SPEED
•
ECM SELECTOR IN ALT
POSITION
• FUEL
INJECTION
MALFUNCTION
• ECM
WARNING
• ECM
FAILURE
• HIGH
RAW
WATER
TEMP.
• LOW
ENGINE
TEMPERATURE
• FUEL
SPILL
•
One Programmable LED
Statistics
Up to 26 statistical points are record-
ed to provide a quick review of how
the system has been operating. The
statistics can be viewed on the main
display, saved to a USB disk drive, or
viewed on the embedded webpage.
Diagnostics
Up to fi fty three diagnostic points are
recorded that can be used to help
in troubleshooting issues with the
controller. The diagnostics can be
viewed on the main display, saved
to a USB disk drive, or viewed on the
embedded webpage.
Message History
Up to10k alarm/status messages can
be stored in the controller memory.
They can be viewed on the main
display, saved to a USB disk drive, or
viewed on the embedded webpage.
DC Fail
A visual indication and audible alarm
is provided to indicate DC power loss
due to one or both batteries being
disconnected from the controller.
This indication will also be provided if
the controller is not operating due to
an electronic board failure.
Programmable Features
• Languages
•
(English, French, Spanish
Standard. Other languages are
available. Consult factory.)
• Date
and
Time
•
Pressure Start and Stop Points
•
Low and High Pressure Alarms
• Stop
Mode
•
Low Suction Shutdown
•
Pressure Recording Parameters
• Run
Period
Timer
•
Weekly Test Timer
• Sequential
Start
Timer
•
AC Failure Alarm
•
AC Fail to Start
Enclosures
Ratings
All FD120 controllers come standard
with NEMA 2 enclosures unless oth-
erwise ordered.
Available options include:
NEMA 3R, 4, 4X, 12.