Defining system parameters
via the STARTUP.INI file
10/10 MN05003003Z-EN
68
Changing settings
The parameters are retained until you enter the browser command
“removestartupini” and then switch the controller off and on
again. The controller will now operate with the parameters of the
project.
Deleting the Startup.INI file
The following browser commands can be used to access the
memory card.
• removestartupini:
Always deletes the controller system parameters. If a memory
card is fitted, the INI file is also deleted on the memory card.
The parameters from the project is accepted next time the
device is switched on.
• removeprojfrommmc:
Deletes the boot project and the INI file on the memory card.
• format:
Deletes the entire memory card incl. INI file.
The behaviour of the Startup.ini file with the Hard Reset and
Factory Set menu commands on the controller and with the
“factoryset” browser command is described in section “Reset” on
page 44.