INSTALLATION INSTRUCTIONS

8

selecting the appropriate Function Code (see Fig-
ure 22).

In the Sequential mode, each output turns on as
specified in Figure 3, only if that output is next in
sequence (see Figure 4). The counter automati-
cally resets and advances the sequence after the
first and second events shown in Figure 4. In the
Reset mode the counter is automatically reset to
zero, in the Preset mode the counter is automati-
cally reset to Preset 2 after the first event and Pre-
set 1 after the second event shown in Figure 4.
The counter does not automatically reset after the
third event unless automatic recycle is pro-
grammed to occur at that output. An automatic
recycle at any event resets both the counter and
the sequence. In the count mode, the Preset
LED’s light to show which Output is next in
sequence.

In the Sequential mode, the reset input or reset
key may be used at any time to reset both the
counter and the sequence. A separate program-
mable input (terminal 16) may be used at any time
to reset the counter without resetting the
sequence.

Turning Outputs Off

Once a transistor output is turned on, it remains on
until it is unlatched. There are five ways to unlatch
each output:

1. Timeout

Each output has a separate timeout function.
The timeout function causes an output to
unlatch after a specified “on” time. The allow-
able time range is from 0.01 to 99.99 seconds.
A value of 0 inhibits the timeout function for
that output. In this case, the output remains on
until unlatched by one of the following meth-
ods.

2. Unlatch at Reset (UAR)

Each output may be programmed to unlatch
when the reset key is pushed or the reset input
is energized (goes low).

3. Latch Until Reset Complete (LURC)

Each output may be programmed to unlatch

when the reset key is released or the reset
input is de-energized (goes high).

4. Unlatch at Alternate Output

Each output may be programmed to unlatch
when one or either of the remaining two out-
puts turns on.

5. Unlatch Inputs

Two programmable unlatch inputs may be
used to unlatch any two of the three outputs.
When an unlatch input is energized, the
selected output unlatches.

Figure 4. Output Sequence Table

Reverse Outputs

Each transistor output may be programmed to
operate in reverse. A reversed output is normally
on (conducts to DC Common) and turns off when
Figure 3 shows that it should turn on. Likewise, a
reversed output turns on when it is timed out or
unlatched.

When power is interrupted, all outputs turn off and
will remain off when power is reapplied. It is there-
fore necessary to “enable” all reversed outputs
after a power interruption. This is usually done by
energizing the appropriate unlatch input(s) or by
programming the reversed outputs to latch until
reset complete and then resetting the control.

,

,

,

,

 WARNING

A POWER OUTAGE CAUSES THE OUT-
PUTS AND RELAYS TO TURN OFF
REGARDLESS OF THE OPERATING
MODE SELECTED. BE SURE THAT
THIS EFFECT IS NOT HAZARDOUS TO
THE OPERATOR.

Event

Sequential Mode

Reset

Preset

First
Second
Third

Output 1
Output 2
Output 3

Output 3
Output 2
Output 1

Summary of Contents for Cutler-Hammer Durant PRESIDENT Series

Page 1: ...DIGIT ELECTRONIC CONTROL TABLE OF CONTENTS 1 General Description 2 Specifications 4 Description of Operating Modes 8 Installation Instructions 14 Installation Instructions Wiring 21 Operation 28 Scal...

Page 2: ...hereafter The war ranties and remedies provided for herein are available to Buyer and shall not extend to any other person COMPLIANCE WITH OSHA Cutler Hammer Eaton Corporation offers no warranty and...

Page 3: ...tion is located in the upper left portion of the panel The keyboard has a Mylar front face and consists of ten data keys 0 through 9 COUNT key RESET key FUNCTION key and ENTER key The 1 key also serv...

Page 4: ...ny of the three above con figurations 5 Count up input with count inhibit input 6 High or low speed operation Low speed oper ation provides maximum immunity to contact bounce and noise The control is...

Page 5: ...7mm maximum without optional spacer provided 077 1 96mm maximum with optional spacer provided Front panel will provide watertight seal with gasket provided Case Material Cadon FRX plastic case with My...

Page 6: ...ate Logical 1 sensor off or contact open Low Speed Low Speed jumpers connected 5 5 msec minimum at 15 VDC 6 800 ohms to DC 7 5 msec minimum at 13 5 VDC 50 000 ohms to DC Low State Logical 0 sensor on...

Page 7: ...ed operation of any transistor outputs COUNTER OPERATING MODES Reset to Zero Reset to Preset Auto Recycle Maintained Reset Momentary DIAGNOSTIC MODES ROM Checksum RAM Bit Test NVRAM Read Write Test NV...

Page 8: ...e counting makes use of two count sig nals which are phase shifted by 90 degrees The detection of which signal is rising first allows the counter to know in what direction the shaft is turn ing When Q...

Page 9: ...tory relay K1 is prewired to Output 1 terminal 8 and relay K2 is prewired to Output 2 terminal 9 Turning Outputs On There are three programmable modes which affect when the transistor outputs turn on...

Page 10: ...function for that output In this case the output remains on until unlatched by one of the following meth ods 2 Unlatch at Reset UAR Each output may be programmed to unlatch when the reset key is push...

Page 11: ...location selected must pro vide for adequate air circulation space around the unit Avoid locating the unit near instruments and or equipment that generate excessive heat Figure 5 shows recommended cu...

Page 12: ...ep all signal lines as short as possible 4 Do not bundle or route signal line s with power carrying lines 5 Tools required are a wire stripper and a small common screwdriver 6 Refer to the setup chart...

Page 13: ...gure 3 for Output 2 8 9 12 AND 21 DC COMMON These terminals are internally connected to the negative side of the DC power supply 10 AND 14 COUNT INPUTS These two count inputs are used to increment or...

Page 14: ...ation of tran sistor outputs in addition to resetting the control The Reset input has the same function as the front panel RESET key 18 DOUBLE INPUT Connecting the DOUBLE INPUT to DC Common selects co...

Page 15: ...and print requests The interface utilized is a standard 20 milliamp current loop with a user selectable Baud rate Terminal 33 is the negative side of the current loop and 34 is the positive side When...

Page 16: ...et and paper backing Do not remove the backing from the remaining outer rim 3 Slide the gasket down the unit until it is in posi tion at the rear of the unit s front bezel The paper backing side shoul...

Page 17: ...INSTALLATION INSTRUCTIONS WIRING 15 Figure 9 230 VAC 47 63 Hz Power Connection Figure 10 12 VDC Power Connection...

Page 18: ...INSTALLATION INSTRUCTIONS WIRING 16 Figure 11 Count Input Wiring Figure 12 Quadrature Encoder Count Input Wiring...

Page 19: ...INSTALLATION INSTRUCTIONS WIRING 17 Figure 13 Encoder with Directional Control Count Input Wiring Figure 14 Add and Subtract Count Input Wiring...

Page 20: ...INSTALLATION INSTRUCTIONS WIRING 18 Figure 15 Remote Reset Wiring Figure 16 Latch Until Contact Closure Wiring...

Page 21: ...INSTALLATION INSTRUCTIONS WIRING 19 Figure 17 Bypass Preset I Input Wiring Figure 18 Using Transistor Outputs to Drive Loads...

Page 22: ...INSTALLATION INSTRUCTIONS WIRING 20 Figure 19 Program Inhibit Wiring Figure 20 Serial Communications to Durant Communications Convertor...

Page 23: ...the pro grammable functions When this key is pressed and followed by 2 digit code the function to be interrogated or modified is selected The FUNCTION key permits the programming of all functions exc...

Page 24: ...return the control to the factory set values after being reprogrammed enter a value of 1 in function 43 FUNCTION FUNCTION CODE ENTRY CHOICES DESCRIPTION CURRENT COUNT VALUE COUNT KEY NONE Shows curre...

Page 25: ...sistor output unlatches Factory set value TRANSISTOR OUTPUT OPERATION 33 0 1 2 3 4 5 6 7 Normal Outputs Reverse Output 1 Reverse Output 2 Reverse Output 1 and Output 2 Reverse Output 3 Reverse Output...

Page 26: ...uts UNLATCH AT RESET 39 0 1 2 3 4 5 6 7 No UAR UAR Output 1 UAR Output 2 UAR Output 1 and Output 2 UAR Output 3 UAR Output 1 and Output 3 UAR Output 2 and Output 3 UAR All Outputs PRESET LOCK Function...

Page 27: ...ormally regardless of whether reset input is held energized or RESET key is continuously being pressed SCALER RESET Model 5886 1400 only 83 0 1 Reset Scaler when Reset key is pressed or when Reset Inp...

Page 28: ...COMMUNICATING TYPE Continued Model 5886 1400 only 5 6 7 X Value 0 1 2 3 Count Preset 1 Preset2 No Transmission of Count Preset 1 or Preset 2 Preset 3 Scale Factor No Transmission of Preset 3 or Scale...

Page 29: ...ange the Pre sets is inhibited whenever possible Function code 41 Preset Lock allows any combi nation of Presets to be inhibited see Figure 21 Any Presets selected in Function code 41 cannot be change...

Page 30: ...Inhibit terminal on the rear panel of the counter must first be dis connected before the Scale Factor may be modi fied To change the Scale Factor follow these steps 1 Press the FUNCTION key The displ...

Page 31: ...lue The display only shows whole increments of counts For example a scale factor of 1 2000 is entered into the counter For each pulse received 1 200 is added to the result But since the display only i...

Page 32: ...plications As a solution a function code has been provided which allows the choice of whether the remaining partial count is carried over into the next cycle or not Function 83 Scaler Reset on Recycle...

Page 33: ...ration of a machine A discussion of the means of calculating the scale factor for each category and special problems involved follows Allowances for Wear or Stretch Over a period of time a measuring w...

Page 34: ...tered into the counter with a scale factor of 1 0000 However when the process is run the parts con sistently come out of the machine only 11 93 inches long The counter is counting 1200 pulses and the...

Page 35: ...d at 12 00 inches as desired Since the material is stretched in the pro cess each pulse received by the counter is worth 1 0308 counts Thus less than 1200 pulses need to be received to produce each 12...

Page 36: ...e factor It is sometimes easier to change the definition of the terms in order to find the scale factor however For example a quadrature shaft encoder which produces 600 pulses per revolution is used...

Page 37: ...pplication is that even if the Preset is set as a multiple of six and only five parts are made per cycle the Preset does not need to be adjusted This is true because the counter checks the preset for...

Page 38: ...racters These are called start and stop bits The start bit signi fies that this is the beginning of the character and the next eight bits are the character itself After the character is transmitted ei...

Page 39: ...ge Return CR and Line Feed LF A printer host computer or other peripheral uses these characters to identify when a transmis sion is complete In the case of the printer the CR instructs it to return th...

Page 40: ...is mode is selected by entering a 1 in Function 92 Upon pressing the RESET key or having the Reset input energized the control internally stores the count value then resets the counter Once the contro...

Page 41: ...are received during a transmission of a new preset but inserts the decimal point automatically after the new preset has been entered upon receipt of the TRANSMITTING SCALE FACTORS For Model 5886 1400...

Page 42: ...ect AC power supply check wiring Counter does not increment or decrement when sensor is activated 1 Sensor malfunction improperly installed or connected 2 Incorrect count mode selected for type of sen...

Page 43: ...erminal 1 Counter counts to preset 1 and recycles Auto recycle mode is selected to auto recycle at preset 1 Check entry at Function 81 Relays and transistor outputs energize but do not deenergize No o...

Page 44: ...between terminals 14 and 12 The display should decrement sev eral counts Make a connection with a short piece of wire between terminals 13 and 12 and repeat the count test between terminals 14 and 12...

Page 45: ...n of the Diagnostics The diagnostics which are included and their related test numbers are as follows 1 ROM Read Only Memory 16 Bit Checksum 2 Internal RAM Random Access Memory Bit Test 3 Non Volatile...

Page 46: ...the Preset 1 Preset 2 and Count LED indicators and moving the decimal point from digit to digit When the display sequence is finished the control shows the count value and the Count indi cator is lit...

Page 47: ...are stocked ratios for encoders Any number from 001 to 600 is available Substitute the desired PPR for XXX in the part numbers 12 Measuring Wheels with 3 8 Bore Aluminum Rimmed 20156 301 Rubber Rimme...

Page 48: ...l BCD To Serial Communications Convertor 58801 411 The Parallel BCD to Serial Communications Convertor PSCC is a parallel BCD to serial Adaptor which provides a means of interfacing a Durant counter w...

Page 49: ...lts and ground referenced inputs from 2 4 volts to 100 volts Relay Module This unit has two relays that may be operated by transistors that are rated to carry at least 075A in a 12 volt circuit Each r...

Page 50: ...Replacement Relay Eaton No 38133 202 Aromat No JW1FEN B DC5V Mounting clip 48433 200 Screw 29801 187 Front Panel Gaskets All Controls 28720 216 Totalizer 5881 0400 28720 215 Front Panel Spacer Adapter...

Page 51: ...Printed in U S A Cutler Hammer 901 South 12th Street Watertown WI 53094 920 261 4070 800 540 9242 FAX 920 261 9097...

Reviews: