OPERATION
25
RESET/PRESET MODE
80
0
1
Reset mode. Counter is reset to zero when the
“RESET” key is pressed or the reset input
(terminal # 17) is energized.
Preset mode. Counter is reset to the Preset 3
number when the “RESET” key is pressed or
the reset input (terminal #17) is energized.
AUTO RECYCLE
81
0
1
2
3
4
5
6
7
No Auto Recycle
Auto Recycle at Output 1.
Auto Recycle at Output 2.
Auto Recycle at either Output 1 or Output 2.
Auto Recycle at Output 3.
Auto Recycle at either Output 1 or Output 3.
Auto Recycle at either Output 2 or Output 3.
Auto Recycle at Output 1, Output 2 or Output 3.
RESET INPUT MODE
82
0
1
Maintained. Counter remains reset until the
Reset input is deenergized or the “RESET” key
is released.
Momentary. Instantaneously reset when input is
energized or when “RESET” key is pressed.
Then allows counter to operate normally
regardless of whether reset input is held
energized or “RESET” key is continuously
being pressed.
SCALER RESET
(Model 5886-1400 only)
83
0
1
Reset Scaler when “Reset” key is pressed or
when Reset Input is energized.
Reset Scaler as above or when counter
performs Auto Recycle.
PRINT REQUEST/RESET
COUNTER INPUT OPERATION
(Terminal 16)
84
0
1
Print Request/Display Latch.
Reset Counter (Functional only in sequential
mode, Function code 85=“4”)
OUTPUT OPERATION
(See Figure 3)
85
0
1
2
3
4
Independent
Prewarn Output 1.
Prewarn Output 2.
Prewarn both Output 1 and Output 2.
Sequential.
COMMUNICATIONS SPEED
90
0
1
2
100 Baud (Send and receive data at 110 bits
per second.)
300 Baud
1200 Baud
COMMUNICATING TYPE
Proper selection of two digits,
“XY,” determines the combination
of values which are transmitted.
“17” transmits no values.
91
“Y” Value
*0
1
2
3
4
Count
Preset 1
Preset 2
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
FUNCTION
FUNCTION
CODE
ENTRY
CHOICES
DESCRIPTION
NOTE: Choices shown with asterisks are the factory set values
Figure 21.
Function Code Programming Table (Continued)