Product information

Introduction

Eaton's Cooper Power™ series four-position sectionalizing 

loadbreak switch is designed for use in transformer oil, 

Envirotemp™ FR3™ fluid, or an approved equivalent-filled 

pad-mounted transformers or distribution switchgear. The 

switches meet the full requirements of the latest revision of 

both IEEE

®

 and IEC standards.

Sectionalizing switches can be used on single- and three-

phase grounded wye or delta systems. They are used in 

underground residential applications with loop feed, and in 

three-phase commercial industrial installations where the 

ability to use an alternative source of power is necessary. 

They can also be used to switch on and off a primary cable 

tap on a transformer.
The under-oil switch can be installed near the transformer 

core/coil assembly, thus minimizing cable capacitance. 

With cable capacitance minimized and all three phases 

switched simultaneously, the like li hood of ferroresonance 

is greatly reduced. All switches are hotstick operable (with 

recommended leverage base) and available in several 

different blade configurations (Refer to Table 8).
Sectionalizing loadbreak switches rotate 360° in either 

direction for alternate source selection. An externally 

installed limiting plate prevents ro ta tion to positions other 

than the one desired. A spring-loaded activating mechanism 

ensures quick loadbreak action and positive contact 

engagement through all positions. 
The Make-Before-Break (MBB) switches provide 

uninterrupted power during switching.

Read this manual first

Read and understand the contents of this manual and follow 

all locally approved procedures and safety practices before 

installing or operating this equipment.

Additional information

These instructions cannot cover all details or variations 

in the equipment, procedures, or process described nor 

provide directions for meeting every possible contingency 

during installation, operation, or maintenance. When 

additional information is desired to satisfy a problem not 

covered sufficiently for the user’s purpose, please contact 

your Eaton representative.

Acceptance and initial inspection

Each sectionalizing switch is inspected and tested at the 

factory. It is in good condition when accepted by the carrier 

for shipment. Upon receipt of a sectionalizing switch, 

inspect it thoroughly for damage and loss of parts incurred 

during shipment. If damage or loss is discovered, file a 

claim with the carrier immediately.

Handling and storage

If the sectionalizing switch is to be stored for an appreciable 

time before installation, provide a clean, dry storage area. 

Quality standards

ISO 9001 Certified Quality Management System

TANK 

WALL

SWITCH

OPERATING 

HANDLE

Figure 1.  Line illustration of sectionalizing switch with 

“Ring-Mount System.”

1

SECTIONALIZING SWITCH INSTALLATION INSTRUCTIONS

  MN800002EN   March 2016

Summary of Contents for COOPER POWER LS4R Series

Page 1: ...Sectionalizing switch installation instructions COOPER POWER SERIES OEM Equipment MN800002EN Effective March 2016 Supersedes June 2015...

Page 2: ...IN ANY EXISTING CONTRACT BETWEEN THE PARTIES ANY SUCH CONTRACT STATES THE ENTIRE OBLIGATION OF EATON THE CONTENTS OF THIS DOCUMENT SHALL NOT BECOME PART OF OR MODIFY ANY CONTRACT BETWEEN THE PARTIES...

Page 3: ...Std C37 71 2001 standard 2 Ratings and characteristics table per IEC 60265 1 2 Dimensional information 2 INSTALLATION PROCEDURE Bolt In assembly 4 Ring Mount assembly 5 Connect internal leads 6 RECOM...

Page 4: ...n Safety information DANGER Hazardous voltage Contact with hazardous voltage will cause death or severe personal injury Follow all locally approved safety procedures when working around high and low v...

Page 5: ...aded activating mechanism ensures quick loadbreak action and positive contact engagement through all positions The Make Before Break MBB switches provide uninterrupted power during switching Read this...

Page 6: ...n phases kV 95 125 150 Across open contacts kV 95 125 150 Power Frequency 1 minute To ground and between phases kV 35 60 70 Across open contacts kV 35 60 70 DC Withstand 15 minutes To ground and betwe...

Page 7: ...n be used on 14 gauge 075 inch 1 9 mm to 25 inch 6 4 mm thick frontplate 14 gauge shown 3 Optional padlock handle is available See catalog section CA800005EN Table 6 and Figure 6 4 See catalog section...

Page 8: ...ng is accomplished with O rings on the operating shaft and gasketed sealing gland secured on the outside of the tank with locking nut 5 Optional install spring small end toward end of shaft and limit...

Page 9: ...ance zone and have an insulated barrier between them and the switch This barrier will deflect any gas bubbles generated by the switch operation The outline drawing shown in Figure 6 describes the swit...

Page 10: ...B A A A A COIL B C COIL C COIL V BLADE MAKE BEFORE BREAK A C B A C B A C B A C B AB C B C OPEN A C LINES A B TO C LINE A ONLY LINE B ONLY TO C TO C OPEN ALL B A C COIL T BLADE BREAK BEFORE MAKE A C B...

Page 11: ...d training may cause excess cantilever force and difficulty in switch operation Figure 6 Arc clearance zone Figure 7 View of tank front with optional limit plate positioned over pin Note With limit pl...

Page 12: ...next position could jam the mechanism making the switch inoperable If the handle stops jams in a position between the designated marked positions stop switching operation and consult the factory prio...

Page 13: ...adbreak devices Failure to follow this warning could result in equipment damage severe injury or death WARNING Hazardous voltage Do not operate loadbreak equipment if a fault condition is suspected Do...

Page 14: ...This page is intentionally left blank 10 SECTIONALIZING SWITCH INSTALLATION INSTRUCTIONS MN800002EN March 2016...

Page 15: ...This page is intentionally left blank 11 SECTIONALIZING SWITCH INSTALLATION INSTRUCTIONS MN800002EN March 2016...

Page 16: ...es Eaton com cooperpowerseries 2016 Eaton All Rights Reserved Printed in USA Publication No MN800002EN Rev 01 Supersedes MN800002EN Rev 00 SAFETY FOR LIFE Eaton is a registered trademark All trademark...

Reviews: