BSPD SPDs for switchgear and power distribution panels 

5.0 Specifications

Table 3. Specifications

Description

Specification

Available system voltages

Three-phase Wye

120/208, 277/480 and 347/600

Three-phase Delta

240, 480 and 600

Input power frequency

50/60Hz

Maximum Continuous Operating Voltage (MCOV)

208Y, and 240D voltage/system type codes 

150 L-N,150 L-G, 150 N-G, 300 L-L 

480Y Voltage/system type code

320 L-N, 320 L-G, 320 N-G, 640 L-L 

600Y Voltage/system type code

420 L-N, 420 L-G, 420 N-G, 840 L-L

480D Voltage/system type code

640 L-G, 640 L-L 

600D Voltage/system type code

840 L-G, 840 L-L

Short-Circuit Current Rating (SCCR) 

200kA

Nominal discharge current (I

n

20kA

Surge current capacity per phase (I

max

120kA, 200kA, 300kA and 400kA ratings available

SPD types

Type 1 (

Basic configuration, can also be used in Type 2 applications) 

Type 2 (s

tandard and standard with surge counter configurations)

Enclosure types

NEMA 1, NEMA 4X

Ports

1

SPD Conductor length/gauge

48” (1.22m) 10AWG stranded copper

Form C contact relay (s

tandard and standard with surge counter configurations only)

Contact ratings 

150Vac or 125Vdc, 1A maximum

Lead length/gauge 

48 inches (1.22m) / 14AWG

Contact logic

Power ON, normal state; N.O. contact = OPEN, N.C. contact = CLOSED  

Power OFF, fault state; N.O. contact = CLOSED, N.C. contact = OPEN

Power consumption

Basic configuration

208Y and 240D voltage/system type codes

0.5W 

480Y and 480D voltage/system type codes

1.1W 

600Y and 600D voltage/system type codes

1.3W

Standard and standard with surge counter configurations

208Y and 240D voltage/system type codes

0.6W 

480Y, and 480D voltage/system type codes

1.7W 

600Y and 600D voltage/system type codes

2.1W

Protection modes 

Three-phase Delta; L-G, L-L 

Three-phase Wye; L-N, L-G, N-G, L-L

Operating temperature / humidity

-40 to +50°C (-40 to +122°F) / 5% to 95%, non-condensing

Operating altitude - ft (m)

16,000 (5000)

EMI/RFI filtering attenuation

Up to 50dB from 10kHz to 100MHz (s

tandard and standard with surge counter 

configurations)

Weight - lbs (kg)

NEMA 1: 120kA-200kA - 6.8 (3.1), 30- 400kA -13.5 (6.1) NEMA 4X: 120-200kA - 14.6 (6.6), 

300-400kA - 21.0 (9.5)

Agency information

Basic, standard and standard with surge counter configurations UL Listed 1449 3rd Edition 

File E316410 Guide VCZA, CSA Certified Notice 516 File 243397

Standard and standard with surge counter  configurations are also UL Recognized 1283 

5th Edition File E316410 Guide VCZA2, CSA Component Acceptance Std. C22.2  

No. 8-M1986 File 243397

Seismic withstand capability

Meets or exceeds the requirements specific to I.B.C. 2006, C.B.C 2007 and U.B.C Zone 4

Warranty

10 Years (see warranty statement 3A1502 for details at www.cooperbussmann.com/Surge)

Summary of Contents for Bussmann Series

Page 1: ...ear and power distribution panels Table of Contents 1 0 Introduction 2 0 Installation 3 0 Operating features 4 0 Troubleshooting 5 0 Specifications 6 0 Catalog number system 7 0 Warranty Instruction S...

Page 2: ...n BSPD units are Type 1 SPDs that can be installed on either the lineside or loadside of the service entrance panel overcurrent protective device The Standard and Standard with Surge Counter configura...

Page 3: ...riations encountered with the installation of a Surge Protective Device SPD nor do they provide for all possible conditions that may be encountered If further information is desired or needed to addre...

Page 4: ...o son parte de ni modifican cualquier acuerdo previo o existente compromiso o relaci n Los t rminos y condiciones de venta de Bussmann constituyen la totalidad de su obligaci n La garant a en los t rm...

Page 5: ...instructions ne fait pas partie ni ne modifie toute entente pr c dente ou existante ni engagement ou relation Les termes et conditions de vente de Bussmann constituent l obligation enti re de Bussmann...

Page 6: ...l cabinet or panelboard The ideal mounting location is as close to the electrical enclosure and electrical connection points as possible The BSPD unit should be mounted in such a way as to minimize le...

Page 7: ...SPDs for switchgear and power distribution panels Instruction Sheet IS10207 Rev 3 Effective July 2015 Figure 5 form C contact relay wire color codes Figure 6 3 phase delta units Figure 7 3 phase Wye...

Page 8: ...the following features Green LEDs Illumination indicates the phase is fully protected and operating normally Note An illuminated green LED on a phase does NOT indicate power ON OFF status just the sur...

Page 9: ...ge Extended Temporary Overvoltage TOV Significant surge event Replace SPD Replace SPD with correct voltage model Check electrical system for TOV sources correct replace SPD Replace SPD One of the disp...

Page 10: ...ower ON normal state N O contact OPEN N C contact CLOSED Power OFF fault state N O contact CLOSED N C contact OPEN Power consumption Basic configuration 208Y and 240D voltage system type codes 0 5W 48...

Page 11: ...ng up to 50dB of noise attenuation from 10kHz to 100MHz 3 Standard With Surge Counter Green and red LEDs per phase to indicate protection status Green and red LEDs on Wye units to indicate protection...

Page 12: ...on Boulevard Cleveland OH 44122 Eaton com Bussmann Division 114 Old State Road Ellisville MO 63021 United States Eaton com bussmannseries 2015 Eaton All Rights Reserved Printed in USA Publication No I...

Reviews: