background image

The instructions in this manual are not intended as a 

substitute for proper training or adequate experience in the 

safe operation of the equipment described. Only competent 

technicians who are familiar with this equipment should 

install, operate, and service it.
A competent technician has these qualifications:
• Is thoroughly familiar with these instructions.
•  Is trained in industry-accepted high and low-voltage safe 

operating practices and procedures.

•  Is trained and authorized to energize, de-energize, clear, 

and ground power distribution equipment.

•  Is trained in the care and use of protective equipment 

such as arc flash clothing, safety glasses, face shield, hard 

hat, rubber gloves, clampstick, hotstick, etc.

Following is important safety information. For safe 

installation and operation of this equipment, be sure to read 

and understand all cautions and warnings.

Safety instructions

Following are general caution and warning statements that 

apply to this equipment. Additional statements, related to 

specific tasks and procedures, are located throughout the 

manual.

Safety for life

!

SAFETY

FOR LIFE

!

SAFETY

FOR LIFE

Eaton meets or exceeds all applicable industry standards relating to product safety in its Cooper Power™ series products. 

We actively promote safe practices in the use and maintenance of our products through our service literature, instructional 

training programs, and the continuous efforts of all Eaton employees involved in product design, manufacture, marketing, 

and service.
We strongly urge that you always follow all locally approved safety procedures and safety instructions when working around 

high voltage lines and equipment, and support our “Safety For Life” mission.

Safety information

DANGER

Hazardous voltage. Contact with hazardous voltage will 

cause death or severe personal injury. Follow all locally 

approved safety procedures when working around high- 

and low-voltage lines and equipment. 

              

G103.3

WARNING 

Before installing, operating, maintaining, or testing this 

equipment, carefully read and understand the contents 

of this manual. Improper operation, handling or 

maintenance can result in death, severe personal injury, 

and equipment damage.                                          

G101.0

WARNING 

This equipment is not intended to protect human 

life. Follow all locally approved procedures and safety 

practices when installing or operating this equipment. 

Failure to comply can result in death, severe personal 

injury and equipment damage.                               

G102.1

WARNING 

Power distribution and transmission equipment must 

be properly selected for the intended application. It 

must be installed and serviced by competent personnel 

who have been trained and understand proper safety 

procedures. These instructions are written for such 

personnel and are not a substitute for adequate training 

and experience in safety procedures. Failure to properly 

select, install or maintain power distribution and 

transmission equipment can result in death, severe 

personal injury, and equipment damage.     

      

             G122.3

This manual may contain four types of hazard statements:

DANGER 

Indicates an imminently hazardous situation which, if 

not avoided, will result in death or serious injury.

WARNING 

Indicates a potentially hazardous situation which, if not 

avoided, could result in death or serious injury.

CAUTION 

Indicates a potentially hazardous situation which, if not 

avoided, may result in minor or moderate injury.

CAUTION 

Indicates a potentially hazardous situation which, if not 

avoided, may result in equipment damage only.

Hazard Statement Definitions

iv

600 A 15/25 KV CLASS PUSH-OP DEADBREAK CONNECTOR INSTALLATION INSTRUCTIONS

  MN650057EN   May 2017   

Summary of Contents for 600 A 15 kV class push-OP

Page 1: ...600 A 15 25 kV class PUSH OP deadbreak connector installation instructions COOPER POWER SERIES Deadbreak Apparatus Connectors MN650057EN Effective May 2017 Supersedes May 2014 S600 13 3...

Page 2: ...TING CONTRACT BETWEEN THE PARTIES ANY SUCH CONTRACT STATES THE ENTIRE OBLIGATION OF EATON THE CONTENTS OF THIS DOCUMENT SHALL NOT BECOME PART OF OR MODIFY ANY CONTRACT BETWEEN THE PARTIES In no event...

Page 3: ...ON Introduction 1 Handling and storage 1 Standards 1 INSTALLATION INSTRUCTIONS Equipment required 2 Cable preparation 2 Install PUSH OP connector on apparatus bushing 5 iii 600 A 15 25 KV CLASS PUSH O...

Page 4: ...formation DANGER Hazardous voltage Contact with hazardous voltage will cause death or severe personal injury Follow all locally approved safety procedures when working around high and low voltage line...

Page 5: ...carrier immediately Handling and storage Be careful during handling and storage of the PUSH OP deadbreak connector to minimize the possibility of damage If the connector is to be stored for any lengt...

Page 6: ...ded longitudinally corrugated wire shielded or UniShield use Eaton s SA series adapter kit with the same cutback dimensions as concentric neutral below If another manufacturer s metallic shield adapte...

Page 7: ...d with the connector Start crimping just below the first line from the spade end of the connector Rotate each successive crimp working towards the cable adapter Do not overlap crimps Clean excess inhi...

Page 8: ...e the alignment segment from the LRTP Recycle the align ment segment See Figure 9 for illustration of completed LRTP installation Step 8 Install probe Place tin plated copper PUSH OP probe with stud o...

Page 9: ...2 Release operating eye from clampstick Push forward on push plate firmly with clampstick until a bump is felt and latch plate fully engages locking teeth Refer to Figure 13a Pull on push plate with c...

Page 10: ...push plate while threading locking pin as this can cause the latch plate to become disengaged from the locking teeth This condition can cause the PUSH OP deadbreak connector to come off of the bushing...

Page 11: ...e to LRTP grounding tab and shroud grounding tab Connect drain wire to PUSH OP body grounding tab and shroud grounding tab Connect one strand of cable concentric neutral to shroud grounding tab Connec...

Page 12: ...s Eaton com cooperpowerseries 2017 Eaton All Rights Reserved Printed in USA Publication No MN650057EN Rev 00 Supersedes S600133 Rev2 SAFETY FOR LIFE Eaton is a registered trademark All trademarks are...