CV3100 series and MINI series high performance general purpose inverter instruction manual
6-9
Diagram 6-2 Rotation deviation frequency compensation
P0.14
Acceleration time 1
Determined by inverter
type
P0.15
Deceleration time 1
Setting range
0.1—3600s
Acceleration time is the time when inverter frequency output increases from 0Hz to
basic frequency, shown in Diagram 6-3 as t1; Deceleration time is the time when
inverter frequency output decreases from basic frequency to 0Hz, shown in Diagram
6-3 as t2.
Diagram6-3Accel. & Decel. Time setting
Output current
Mortor Rev
After
compensation
Befor
compensation
50
%
100
%
150
%
Ratation deviation
Compensation 100%
fb
Output
frequency
time
t1