CV3100 series and MINI series high performance general purpose inverter instruction manual
6-39
Analog output width or pulse output frequency is positively proportional to inverter
output current.
AO1
:(
0- AO1 upper limit
)
~
(
0.0- twice rated current
)
DO3
:(
0- DO3 upper limit
)
~
(
0.0-twice rated current
)
3
:
Motor rev.
Analog output width or pulse output frequency is positively proportional to motor rev.
AO1
:(
0- AO1 upper limit
)
~
(
0- motor synchronous speed
)
DO3
:(
0- DO3 upper limit
)
~
(
0- motor synchronous speed
)
4
:
Output voltage
Analog output width or pulse output frequency is positively proportional to inverter
output voltage.
AO1
:(
0- AO1 upper limit
)
~
(
0-maximum/rated output voltage
)
DO3
:(
0- DO3 upper limit
)
~
(
0-maximum/rated output voltage
)
5
:
Bus voltage
Analog output width or pulse output frequency is positively proportional to inverter
bus voltage.
AO1
:(
0- AO1 upper limit
)
~
(
0-800V
)
DO3
:(
0- DO3 upper limit
)
~
(
0-800V
)
6
:
PID ration
Analog output width or pulse output frequency is positively proportional to PID ration.
AO1
:(
0- AO1 upper limit
)
~
(
0.00-10.00V
)
DO3
:(
0- DO3 upper limit
)
~
(
0.00-10.00V
)
7
:
PID feedback
Analog output width or pulse output frequency is positively proportional to PID
feedback.
AO1
:(
0- AO1 upper limit
)
~
(
0.00-10.00V
)
DO3
:(
0- DO3 upper limit
)
~
(
0.00-10.00V
)
P5.11
AO1 gain setting
Factory setting
100%
Setting range
20—200%
P5.13
DO3 gain setting
Factory setting
100%
Setting range
20—200%
P5.12
Reserved
P5.14
Reserved
P5.11 defines the upper limit output of AO1. When the factory setting is 100%, the