Adjustments and Replacements
1C7833 – July 1995
2–23
Replacement of the GAS SPRING
Figure 2–26
Replacement of the GAS SPRING
[1] De-energize the PROCESSOR. See Page 2–5.
[2] Do the General Access procedure on Page 2–6 as
required.
[3] Lift the SORTER, and hold it with your left hand.
Warning
The SORTER weighs 20 kg (45 lb). Hold the SORTER
while you release the GAS SPRING from the MOUNT.
[4] Continue holding the SORTER in the up
position with your left hand, and pry the
RELEASE CLIP with a SCREWDRIVER while
pulling the GAS SPRING from the top MOUNT.
See the figure.
[5] Continue holding the SORTER in the up position
with your left hand, and release the RELEASE
CLIP on the bottom MOUNT.
[6] Remove the GAS SPRING from the SORTER.
[7] Install the new GAS SPRING with the larger end
down. See the figure.
H127_2012GA
H127_2012GCA
SPRING
GAS
2 MOUNTS
SCREWDRIVER
CLIP
RELEASE