3. EarthLinked
®
Domestic Water Heating (DWM) Applications
Figure 3a illustrates the installation of GSTE storage water heater with a Domestic Water
Module for a residential heating application. Location of the GSTE storage water heater from
the DWM is to be no more than 10 ft. apart. Water piping and connections between the
compressor unit and tank are all 1-1/2” Type L copper for the models DWM-4248 and DWM-
6072
.
Piping and connections are 1” Type L copper for model DWM-1836. Detail for the ports
and connections on top of the storage water heater are shown in Figure 3b. The electrical field
wiring for the electric heater element and thermostat are illustrated in Figure 3c.
Figure 3a. Domestic (DWM) Water Heating Application